Back to search

Monterey, California. Naval Postgraduate School

Analysis of the sensitivity of multi-stage axial compressors to fouling at various stages

Abstract

dc:description.abstract

This thesis presents a simple, meanline analysis of the impact of blade roughness on the mass flow, work coefficient, and efficiency of a three-stage axial compressor as a function of the location of fouling. First, an extensive review is presented on the state-of-the-art of measuring compressor degradation and on the impact of roughness on loss and deviation in a compressor cascade. The performance of a baseline, three-stage compressor, which has hydrodynamically smooth blades, is predicted. Using this baseline geometry, the influence of roughness in the front, middle and rear stages is calculated using empirical data for the enhanced losses and increased deviation, with a stage stacking technique. Influence coefficients that relate percentage changes in one parameter to percentage changes in other parameters are calculated. This analysis predicts that the most sensitive parameter for predicting fouling in the front stages is the percentage change in mass flow and the most sensitive parameter for predicting fouling in the rear stages is the efficiency.

Degree

thesis:*
Name thesis:degree_name
M.S. in Mechanical Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
Monterey, California. Naval Postgraduate School
Year dc:date.issued
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Baker, Jonathan D.
Advisor dc:contributor.advisor
  • Millsaps, Knox T., Jr.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/2916

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Baker, Jonathan D.. Analysis of the sensitivity of multi-stage axial compressors to fouling at various stages. Masters thesis, Monterey, California. Naval Postgraduate School, 2002. https://hdl.handle.net/10945/2916