Monterey, California. Naval Postgraduate School
Comparative design analysis of a fuel cell powered Coast Guard cutter
Abstract
dc:description.abstractThis investigation studied the impact of using fuel cells as the primary power source in a ship design. Three different fuel cells were modeled: Phosphoric Acid, Proton Exchange Membrane, and Molten Carbonate. These models were compared against a baseline design containing a more conventional powerplant. The models were built and optimized using the 'Advanced Surface Ship Evaluation Tool' (ASSET/MONOSC). Specifically, payload, endurance, sustained speed, and hull depth were held constant, while length, beam, and draft were optimized to provide a balanced design. Full load displacement and required fuel load were compared against the baseline values. Conclusions concerning the potential value of a fuel cell powerplant were drawn.
Degree
thesis:*- Name thesis:degree_name
- M.S in Mechanical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor dc:publisher
- Monterey, California. Naval Postgraduate School
- Year dc:date.issued
- 1996
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Comar, John Francis.
- Advisor dc:contributor.advisor
-
- Calvano, C.N.
Rights
dc:rights- Statement dc:rights
-
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/32069