Abstract
dc:description.abstractA study has been made on the possibility of identifying faulty components of a network by making tests only on external points of that network. The conclusion is made that this is possible, and that a practical method of doing this can be developed from the computer program presented as a result of this investigation. The method used is to select the voltage transfer functions of a network as the quantities on which the tests will be made. The poles and zeros of these functions are used to select a set of test frequencies. From the measurements made at these frequencies, a set of signatures is available which allow the faulty components to be identified.
Degree
thesis:*- Name thesis:degree_name
- M.S.in Electrical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Electrical Engineering
- Department dc:contributor.department
- Department of Electrical Engineering
- Grantor
- Naval Postgraduate School
- Year dc:date.issued
- 1969
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Dyer, James Richard
- Advisor dc:contributor.advisor
-
- Chan, S.G.
Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/40131