Utilizing an energy management system with distributed resources to manage critical loads and reduce energy costs

Abstract

dc:description.abstract

Energy security is critical to the DOD and can be achieved using different methods, but for DOD installations cost effectiveness must be taken into consideration when evaluating energy security goals. Energy Storage Systems (ESSs) have a wide range of associated technologies as well as large differences in cost and capabilities. This study examines the cost effectiveness of utilizing an ESS to perform peak shaving with an Energy Management System (EMS). An EMS used with an ESS can perform several functions that can be beneficial to the grid. These functions include peak shaving, conducting power factor correction, matching critical load to most efficient distributed resource, and islanding a system during commercial grid disruption. While utilizing an ESS within a microgrid allows several benefits, to include peak shaving, the ability to utilize photovoltaic arrays during islanding, and power factor correction, the implementation of the ESS by itself is likely to prove cost prohibitive. The DOD requires energy projects to have net savings over the life cycle of the project and in areas without high differential between peak power and off-peak power, this goal will be difficult to achieve.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Electrical Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Electrical Engineering
Department dc:contributor.department
Electrical and Computer Engineering (ECE)
Grantor dc:publisher
Monterey, CA; Naval Postgraduate School
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gustafson, David J.
Advisors dc:contributor.advisor
  • Julian, Alexander L.
  • Oriti, Giovanna

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/43921

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Gustafson, David J.. Utilizing an energy management system with distributed resources to manage critical loads and reduce energy costs. Masters thesis, Monterey, CA; Naval Postgraduate School, 2014. https://hdl.handle.net/10945/43921