Back to search

Old Dominion University

Plain and Steel-Reinforced Concrete Shear Walls With and Without CFRP Retrofitting

Abstract

dc:description.abstract

This thesis presents the outcome- of a study of the behavior and strength of plain and steel-reinforced concrete shear walls with and without a window opening and Carbon Fiber-Reinforced Polymer (CFRP) retrofitting. A total of seven tests were conducted using six different shear walls. Each wall was subjected to a gradually increasing static load at one of it's top corners until the maximum load was reached. The load-deflection relations and the walls' failure patterns were observed and recorded. It was found that the window opening in the plain concrete wall reduced the wall load capacity by 18 percent. For the wall without an opening, CFRP retrofitting provided a dramatic 63.4 percent increase in the ultimate strength. The steel reinforced wall with an opening experienced a surprising 21 percent reduction in the ultimate load relative to that for the plain concrete wall. It was also found that the ACI Code is seriously unconservative for the plain concrete wall without opening; however, it is conservative for the steel-reinforced wall. Likewise, the ETABS software based on the finite element method gave seriously flawed load-deflection curves. On the contrary, a strut-and-tie model developed and presented in this thesis for the steel reinforced wall without opening is found to be in good agreement with the experimental results.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Civil & Environmental Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Aloosi, Ali Mohammed Salih Al
Contributors dc:contributor
  • Zia Razzaq
  • Isao Ishibashi
  • M. B. Sirjani

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • <p>In Copyright. URI: <a href="http://rightsstatements.org/vocab/InC/1.0/">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.odu.edu/cee_etds/157

Chain of custody

source
Harvested from
Old Dominion University
Base URL
digitalcommons.odu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Aloosi, Ali Mohammed Salih Al. Plain and Steel-Reinforced Concrete Shear Walls With and Without CFRP Retrofitting. Thesis thesis, https://digitalcommons.odu.edu/cee_etds/157