Back to search

Old Dominion University

Use of <sup>52</sup>Cr for the Quantitative Determination of Red Cell Volume

Abstract

dc:description.abstract

Chromium-52 has recently been suggested for use as a new agent to label red cells for the in vivo quantitation of red cell volume (1). In this paper, the development and validation of a routine 52cr labeling procedure is described. The accuracy, precision, and detection limits of chromium analysis by Zeeman effect atomic absorption spectroscopy was evaluated in the concentration range of 1 - 10 ug Cr/L. Red cell chromium uptake was evaluated as a function of time, temperature, and concentration. Red cells labeled with a 2.5 mg/L chromium solution for 30 minutes at room temperature exhibited optimal label uptakes for the parameters studied. From these results, a minimal chromium dose was identified to achieve accurate in vivo quantitation. Glutathione reductase and peroxidase enzyme activities, and cellular osmotic fragility were assayed as a function of chromium concentration. Glutathione peroxidase activity and osmotic fragility of cells collected in ACD solution were not significantly affected to chromium labeling concentrations of 25 mg/L. Glutathione reductase activities were reduced by approximately 14 % at 2.5 mg Cr/L, which is not significant clinically. The accuracy of the developed 52cr labeling procedure was evaluated in vivo in eight subjects by simultaneous determination of red cell volume using 1251-Albumin, 51cr, 52cr, and the Dubois-Hurley method of red cell volume estimation (2). The results provide conclusive evidence that chromium-52 can be used for the accurate, quantitative determination of red cell volume by the developed procedure.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Chemistry & Biochemistry

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hanbury, Claude Michael
Contributors dc:contributor
  • Patricia A. Pleban
  • W. A. Heaton
  • Kenneth G. Brown

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • <p>In Copyright. URI: <a href="http://rightsstatements.org/vocab/InC/1.0/">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.odu.edu/chemistry_etds/108

Chain of custody

source
Harvested from
Old Dominion University
Base URL
digitalcommons.odu.edu/do/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Hanbury, Claude Michael. Use of <sup>52</sup>Cr for the Quantitative Determination of Red Cell Volume. Thesis thesis, https://digitalcommons.odu.edu/chemistry_etds/108