Back to search

Old Dominion University

Real-Time Measurements on the Effects of Ultra-Short High Voltage Pulses on HL-60 Cells

Abstract

dc:description.abstract

The application of high voltage microsecond pulses that are above a critical value, to biological cells, has been shown to cause electroporation (Neumann, 1989). In addition, ultra-short pulses of several tens to hundreds of nanoseconds duration have been recently shown to affect intracellular structures without disturbing the plasma membrane (Schoenbach, 2001). However, such ultra-short intense pulses are expected to cause deformation of cells due to Maxwell stresses. This deformation was studied by means of an imaging technique with 10 ns temporal resolution on HL-60 cells. The imaging system consists of an inverted microscope where a spark light source was used to illuminate the sample. The microscope slide, having two stainless steel electrodes with a gap distance of 100 μm, is placed under the microscope. The electrodes are connected to a Blumlein generator, which generates high voltage pulses 10, 60 and 300 ns long. With a load resistance of 100 Ω , the impedance of the pulse forming line is matched to the resistance of the cells in suspension between the electrodes, generating a nearly rectangular pulse. This pulse can be applied with a maximum voltage of 850 V, corresponding to an electric field of 85 kV/cm. To achieve the desired temporal resolution, we use a high intensity nanolamp with a peak output power of 500 kW, which emits a white spectrum flash of light for only 10 ns. Pulse generator and nanolamp are synchronized with a CCD camera attached to the microscope. Light flash and electric pulse can then be shifted in time against each other as needed, to observe various effects. It was found that pulsed electric fields (PEFs) of 85 kV/cm with 300 ns duration, caused two different effects depending upon the medium of the cell suspension. In low conductivity media, HL-60 cells underwent elongation in the field direction. The horizontal axis increased up to 5.4%, whereas the vertical axis decreased by 2.1%. In higher conductivity or physiological media under the same conditions, HL-60 cells showed negligible deformation effects.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Electrical & Computer Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Artemiou, Michalis C.
Contributors dc:contributor
  • Karl H. Schoenbach
  • Mounir Laroussi
  • Richard Nuccitelli
  • R. James Swenson
  • Stephen Beebe

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • <p>In Copyright. URI: <a href="http://rightsstatements.org/vocab/InC/1.0/">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.odu.edu/ece_etds/275

Chain of custody

source
Harvested from
Old Dominion University
Base URL
digitalcommons.odu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Artemiou, Michalis C.. Real-Time Measurements on the Effects of Ultra-Short High Voltage Pulses on HL-60 Cells. Thesis thesis, https://digitalcommons.odu.edu/ece_etds/275