Back to search

Old Dominion University

Modeling Nerve Electro-Stimulation in the Nanosecond Regime

Abstract

dc:description.abstract

Numerical simulations of electrical stimulation of frog gastrocnemius muscles have been carried out for pulse durations in the nanosecond regime. There are a number of potential advantages in using ultra-short pulses for neural stimulation, and no previous electro-stimulation work in the sub-microsecond regime has been reported. A timedependent, three-dimensional analysis model was developed and implemented for three distinct situations: (i) direct stimulation via electrode contact, (ii) indirect excitation based on electrodes immersed in a saline-filled bath, and (iii) remote electromagnetic stimulation through vacuum. The simulations yielded strength-dm ation (S-D) curves with pulse durations as short as 5 ns. Good agreement between the model predictions and experimental measurements was obtained. For example, with direct contact a peak current of about 30 A was predicted for the shortest pulse; the measured value was 34 A. The modeling also led to a demonstration of the non-thermal nature of electro-stimulation with nanosecond pulses, even with an applied voltage as high as 5 kV. Calculations of the S-D curves for both direct and indirect stimulation yielded a good match with the available experimental data. The verified model was used to investigate the effects of electrode placement and pulse shape, and a new anode-cathode-anode electrode scheme was developed for direct stimulation. A time constant of 160 μs was estimated for frog tissue stimulation; this value is indicative of a nerve-based response. Furthermore, it was shown quantitatively that inhomogeneities in the nerve geometry and size can affect the S-D curve. For electrical stimulation, the greatest potential for muscle twitching occurs at boundaries and within regions that have internal non-uniformity of nerve fiber size or potential distribution. For electromagnetic stimulation, the simulations demonstrated that the electromagnetic wave could not penetrate the muscle very effectively. However, nonuniformity of electric field distribution was observed, and this is a desirable pre-requisite for enhancing the activating function for a bio-response.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Electrical & Computer Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chen, Feng
Contributors dc:contributor
  • Ravindra P. Joshi
  • Linda L. Vahala
  • Mournir Laroussi

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • <p>In Copyright. URI: <a href="http://rightsstatements.org/vocab/InC/1.0/">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.odu.edu/ece_etds/307

Chain of custody

source
Harvested from
Old Dominion University
Base URL
digitalcommons.odu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Chen, Feng. Modeling Nerve Electro-Stimulation in the Nanosecond Regime. Thesis thesis, https://digitalcommons.odu.edu/ece_etds/307