Back to search

Old Dominion University

Distal Placement of an End-To-Side Bypass Graft Anastomosis A 3-D Computational Study

Abstract

dc:description.abstract

A three-dimensional computational fluid dynamics study of blood flow through stenotic arteries has been conducted. Flow phenomena, such as separation regions and turbulence, can be found distal to an arterial stenosis. Frequently, a bypass graft using an end-to-side technique is attached to a stenotic artery to restore adequate blood flow. However, a significant percentage of these grafts fail after thirty postoperative days due to intimal hyperplasia development around the distal anastomosis. Moreover, aberrant wall shear rates have been implicated as a factor in the development of intimal hyperplasia. Thus, the present study examines whether placement of the distal end of a bypass graft anastomosis in the post-stenotic region of blood flow influences shear rates around the distal anastomosis, thereby establishing the possibility of an optimal distal placement that extends patent blood flow achieved by the bypass operation. Therefore, different graft attachment locations were studied using a 51 % and a 75% stenotic arterial model. Steady, incompressible, Newtonian flow was assumed and simulated on a locally structured multi-block mesh with hexahedral elements. Furthermore, a finite-volume method and a pressure correction scheme, SIMPLE, were used in addition to implicit Gauss-Siedel iteration to solve the full Navier-Stokes equations and turbulent kinetic energy and specific dissipation rate equations with second-order accuracy. A preliminary study was conducted and confirmed acceptable prediction accuracy of the present computational code and technique. Consequently, the highest shear rates were recorded around the bypass graft anastomosis placed farthest downstream from the stenosis for both 51% and 75% stenotic models. Moreover, the lowest inner wall shear rates were recorded around the distal bypass graft anastomosis of the 51 % stenotic model placed in a separation region, and the lowest outer wall shear rates were recorded around the distal bypass graft anastomosis of the 75% stenotic model placed in the reattachment region of separated flow. This indicates that distal placement of an end-to-side bypass graft anastomosis influences shear rates around the distal anastomosis, and with further study, an optimal placement could be determined that possibly extends patent blood flow to afflicted tissues.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Mechanical & Aerospace Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Di Cicco, John Robert
Contributors dc:contributor
  • Ayodeji Demuren
  • Arthur C. Taylor III
  • Sebastian Bawab

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • <p>In Copyright. URI: <a href="http://rightsstatements.org/vocab/InC/1.0/">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.odu.edu/mae_etds/476

Chain of custody

source
Harvested from
Old Dominion University
Base URL
digitalcommons.odu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation