Back to search

Old Dominion University

Assessment of a Higher Harmonic Control System for Minimizing Vibrations on a Dynamically Scaled Tiltrotor Model

Abstract

dc:description.abstract

The performance of a higher harmonic control system called the Multipoint Adaptive Vibration Suppression System (MA VSS) at reducing 3/rev wing vibratory loads and fuselage vibrations on a dynamically-scaled tiltrotor model is presented. Previous wind tunnel tests on a semispan aeroelastic tiltrotor model have demonstrated the effectiveness of MAVSS for reducing wing vibratory loads using both an active flaperon and swashplate. The primary goal, however, of such a vibration suppression system is to reduce tiltrotor fuselage vibrations in order to improve passenger comfort. The present study addresses the reduction of both wing and fuselage vibrations using MA VSS active flaperons on a 1/10-scale dynamic tiltrotor model designed to be representative of a tiltrotor configuration. Also, this study attempts to identify possible problems that may impede the application of MA VSS flaperon control forces for the purpose of tiltrotor vibration reduction in the presence of full-span symmetric and antisymmetric wing modes of vibration. Electromagnetic shakers applied simulated 3/rev vibratory hub loads and higher harmonic control forces, simulating active flaperons, to the tiltrotor model. MAVSS is shown to be effective at reducing individual and combined 3/rev vibratory wing loads in the semispan configuration. For the more complex full-span configuration, MAVSS flaperon control forces are shown to be effective at reducing wing vibratory loads or fuselage vertical accelerations, but not as effective at reducing wing loads and fuselage vibrations simultaneously. Vibration reduction trends are shown to be a function of the simulated rotor speed for both the semispan and full-span configurations. These results suggest that the application of MA VSS-controlled flaperons to a tiltrotor configuration may prove to be difficult due to elevated wing vibratory loads during reduction of fuselage vibrations and because wing vibratory loads and fuselage vibrations cannot be reduced simultaneously.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Mechanical & Aerospace Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Piatak, David J.
Contributors dc:contributor
  • Donald L. Kunz
  • Raymond G. Kvaternik
  • Mark W. Nixon
  • Jeng-Jong Ro

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • <p>In Copyright. URI: <a href="http://rightsstatements.org/vocab/InC/1.0/">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.odu.edu/mae_etds/664

Chain of custody

source
Harvested from
Old Dominion University
Base URL
digitalcommons.odu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Piatak, David J.. Assessment of a Higher Harmonic Control System for Minimizing Vibrations on a Dynamically Scaled Tiltrotor Model. Thesis thesis, https://digitalcommons.odu.edu/mae_etds/664