Abstract

dc:description.abstract

The In-situ Load System (ILS) was designed at NASA Langley Research Center (LaRC) to perform multi-component check loads on a force balance at a test facility. The ILS is designed to allow a force balance to be placed at off nominal orientations, while maintaining an applied load in the gravitational direction. This allows for multicomponent loads to be applied to a balance as a function of balance orientation and ILS configuration. The system is designed to be used in conjunction with a facilities existing pitch and roll control systems. The ILS was modified to provide higher load ranges than those permissible on the original design. The modification allowed movement of the load application point in two dimensions. These modifications allow the ILS to generate close to full scale moments and a greater load combination range than the original design. The modifications facilitated exercising a balance over larger load ranges, hence improving the effectiveness of a check load or calibration schedule. Stress analyses were performed to ensure that structural integrity was not compromised by the modifications. A tare method was implemented to remove the loads generated by the unloaded ILS system. The method uses unloaded points that straddle a loaded data point, resulting in reduced experimental time due to the lack of pre- and post-test tare schedules. A regression on the unloaded data was created using the g-vector output from the angle measurement system (AMS) as well as a multiple linear regression. Several sets of experiments were conducted on the ILS to evaluate the system's performance to applied known loads. The results from the experiments provided mixed results of the systems performance. Several results showed that the system can replicate a given load within acceptable uncertainty bounds for several of the load components. Conversely the total calculated load, the root sum squared of the force components, was found to be on average 2.5 pounds higher than was expected. A Monte Carlo simulation was conducted to investigate the effect of a small change in the calibration coefficients. The simulation assumed that the standard deviations of the calibration coefficients and the primary sensitivities are a percentage of their estimated values. The simulation has shown that small changes in the primary sensitivities can lead to significant changes in the estimated load. It was also shown that small changes in the interaction calibration coefficients do not to have a significant change on the estimated load compared to the primary sensitivities.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Mechanical & Aerospace Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Toro, Kenneth
Contributors dc:contributor
  • Drew Landman
  • Onur Bilgen
  • Colin Britcher
  • Sean Commo

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • <p>In Copyright. URI: <a href="http://rightsstatements.org/vocab/InC/1.0/">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.odu.edu/mae_etds/714

Chain of custody

source
Harvested from
Old Dominion University
Base URL
digitalcommons.odu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Toro, Kenneth. Development and Assessment of an In-Situ Load System. Thesis thesis, https://digitalcommons.odu.edu/mae_etds/714