An Evaluation of an Electromagnetic Current Meter for Study of Water Particle Motion

Abstract

dc:description.abstract

A new sophisticated electromagnetic current meter was laboratory and field tested in a wide variety of applications, ranging from measurement of net bottom currents (primarily tidal origin) on the continental shelf, to horizontal and vertical components of wave induced orbital motion of waves with periods as small as one second. These tests indicate that this instrument is capable of performing to at least the following specifications, subject to the comments which follow: Speed range: Accuracy: Threshold: 0 to + 5 knots + 0.2 knots + 0.02 knots Response time: 0.25 sec. Direction: -+ 7 degrees Depth: '0 to 42 feet A single check of 7.5 knots was made in the 0 to 10 knot range. This was within specifications. The sensing probe has no moving parts. It senses two orthogonal components of the average instantaneous current (in a plane perpendicular to the axis of the probe) in an area approximately 4.5 inches in radius. Each of the two pairs of sensing plates will give an essentially undistorted cosine response of flow not parallel to the plane of the plates. Because of the great sensitivity and rapid response of the meter, the design of the mount must minimize structural responant frequencies (in situ) within the spectrum of interest. When this is not possible, on site observations can be made to record natural resonant frequencies of the mounting system. The output level of the equipment. is virtually independent of temperature and salinity, although when employed in fresh water the signal to noise ratio decreases noticeably. There is no noticeable effect of the presence of local electrolytic potentials, but there is an indication that some factor in the local environment can create a zero offset. that must be detected and measured by 180 rotation of the sensor. A computer program easily normalizes such data. Measurements made less than three feet from a sharp magnetic discontinuity will be unreliable. However measurements within one foot of the surface and one-half foot of a sand bottom remain within specified accuracy. Input power variations of ± 20 volts or less do not affect the output. Minor (5%) variations from 60 cycles similarly cause no problem except perhaps in ancillary recording equipment.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Ocean & Earth Sciences

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hecker, George Milton
Contributors dc:contributor
  • Ronald E. Johnson
  • Donald J. P. Swift
  • William J. Hanna
  • Rudolf P. Savage

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • <p>In Copyright. URI: <a href="http://rightsstatements.org/vocab/InC/1.0/">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.odu.edu/oeas_etds/222

Chain of custody

source
Harvested from
Old Dominion University
Base URL
digitalcommons.odu.edu/do/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Hecker, George Milton. An Evaluation of an Electromagnetic Current Meter for Study of Water Particle Motion. Thesis thesis, https://digitalcommons.odu.edu/oeas_etds/222