Perivascular Drug Delivery Systems for the Inhibition of Intimal Hyperplasia
Abstract
dc:descriptionThe long-term clinical success of autologous vein and synthetic vascular grafts is limited due to the development of anastomotic intimal hyperplasia (IH). Previously published data suggests that cyclosporine (CyA) (an immunosuppressive drug) may reduce the development of IH in a canine model [1]. However, systemic administration of CyA could create serious adverse effects. Therefore, it is our long-term goal to test the hypothesis that the controlled local release of cyclosporine from a polymeric vascular wrap will prevent the development of IH. In order to test this hypothesis, we developed three controlled release polymeric devices that could be placed around vascular graft anastomotic sites to deliver therapeutic drugs locally. The first device is a poly(ethylene glycol) (PEG) hydrogel sheet. The second device is a composite device consisting of poly(DL-lactide-co-glycolide) (PLGA) microspheres dispersed in the PEG hydrogel sheet. The third device is in the form of a ring (referred to as PolyRing from here on) that can be slipped around the anastomotic sites. PolyRing is a composite polymeric device consisting of PLGA microspheres embedded in a PEG hydrogel. In-vitro studies were conducted on the three devices to evaluate the effects of different sterilization procedures on the properties of the device. It was determined that gamma sterilization was the preferred sterilization method of choice. In-vivo studies were conducted on a swine model to evaluate the biocompatibility, drug optimization and efficacy of PolyRing. The biocompatibility study utilized four (4) domestic swine with non-drug loaded PolyRings harvested at two (2) and four (4) week time points. PolyRings (ID 3-5 mm; OD 7-8 mm; Length 5 mm) were implanted in subcutaneous and muscular tissues and around jugular veins and carotid arteries. The histological findings of gamma sterilized PolyRing implants at two and four weeks demonstrated the biocompatibility of this device. A minimal foreign body reaction with macrophages and foreign body giant cells was identified at the tissue/material surfaces at both two and four week implantation periods. This is a normal and expected finding for biocompatible materials. The drug optimization study utilized three (3) domestic swine with CyA-loaded PolyRings harvested at one (1) week. The drug loaded PolyRings were implanted around jugular veins and carotid arteries. The drug optimization studies revealed a proportional increase in the concentration of CyA in tissue with the concentrations of the drug loaded within PolyRing. The systemic circulation showed concentrations less than the sensitivity of the assay (25 ng/ml). Hence, we were able to achieve truly local concentrations of the drug using the device PolyRing.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Chemical Engineering
- Grantor dc:publisher
- University of Akron
- Year dc:date
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kanjickal, Deenu George
- Contributors dc:contributor
-
- Lopina, Stephanie
Subjects
dc:subject × 9Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=akron1133715441