Back to search

University of Akron

A STUDY OF NON-CONTACTING PASSIVE-ADAPTIVE TURBINE FINGER SEAL PERFORMANCE

Abstract

dc:description

The purpose of this research was the analysis and design optimization of a compliant seal configuration as a replacement to brush seals in gas turbine engines. The outcome of this included original contributions in the areas of finger seal design methodology, finger seal back plate design, and finger seal dynamics modeling. To accomplish the research goal, the analyses covered four autonomous yet interrelated areas: solid mechanics analysis, thermofluid analysis, dynamics analysis, and experimental analysis. The solid mechanics analysis showed the relationship between the design of the finger seal parameters and the integrity of the finger response to various loadings. Specifically, a relationship between the geometric dimensions of the seal and the stiffness of the fingers was established. Additionally presented in this section are the original design algorithm and the original back plate design. The design algorithm identified eight fundamental finger seal parameters which allow the seal designer to change the geometric and operational characteristics of the individual fingers in order to tune the seal to its optimum usage. The thermofluid analysis showed the relationship between the finger pad shape and its lift characteristics. Included in this analysis was a solid-fluid interaction model used to characterize under pad pressure and force, fluid leakage, and finger lift as a function of both rotor speed and high- to low-side pressure differential. Hydrostatic and hydrodynamic lifting capabilities were isolated for each wedge configuration. The original dynamics model demonstrated the motion of the finger seal as it interacted with the rotor. The final model incorporated finger-rotor interaction, finger free motion, and the effects of the Coulomb friction damping. Finally, the experimental analysis provided data of the finger seal performance for preliminary verification of the aforementioned models as well as for assessment of the seal configuration tested. Experimental data included test section pressures, finger pad temperatures, and seal leakage as a function of rotor speed and pressure differential. The experimental data provided insight into the functionality of the finger seal as well as verified temperature and leakage trends established by the analytical models. The function of the pressure balance back plate was also confirmed.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Marie, Hazel
Contributors dc:contributor
  • Braun, Minel

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Marie, Hazel. A STUDY OF NON-CONTACTING PASSIVE-ADAPTIVE TURBINE FINGER SEAL PERFORMANCE. doctoral thesis, University of Akron, 2005. http://rave.ohiolink.edu/etdc/view?acc_num=akron1134587932