Back to search

University of Akron

Reliable Invasive Blood Pressure Measurements Using Fourier Optimization Techniques

Abstract

dc:description

Arterial blood pressure is a basic hemodynamic variable routinely monitored in critical care. Conventionally, it is measured invasively using a fluid-filled catheter-transducer system. However, the dynamic characteristics of the system, which may be affected by variation in assembly, air entrapment, and clotting, often result in waveform distortion and inaccurate measurements. The current study proposed and developed a novel method for approximating and reproducing the true blood pressure waveform using numerical optimization technique. This method employed a counter pressure source in tandem with the transducer. The properties of counter pressure waveform are generated by 16 Fourier coefficients, which are manipulated iteratively by the optimization algorithm to minimize the fluid flow in the pressure monitoring system. When the flow is zero, no energy is lost and the counter pressure waveform closely approximates the true pressure waveform. To validate the method, the catheter-transducer system with the addition of counter pressure source was simulated and tested with three blood pressure waveforms and air bubbles of five sizes at five locations in the system. The method was successful in reproducing the true blood pressure waveforms regardless of variations in the system characteristics and changes in the system over time. The method developed for this research provides more accurate measurements than contemporary catheter-transducer systems.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lim, Lily
Advisor dc:contributor.advisor
  • Taylor, Bruce

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Lim, Lily. Reliable Invasive Blood Pressure Measurements Using Fourier Optimization Techniques. masters thesis, University of Akron, 2006. http://rave.ohiolink.edu/etdc/view?acc_num=akron1145285836