University of Akron
STRAIN CONCENTRATION AND TENSION DOMINATED STIFFENED AEROSPACE STRUCTURES
Abstract
dc:descriptionThrough the years, aerospace structural systems have progressively changed and incrementally evolved. These changes have resulted from the conjoint influence of weight and cost of the system while concurrently being influenced by improvements in the material and/or alloy system that is chosen and used. The purpose of this research document (‘thesis’), entitled: “Strain Concentration and Tension Dominated Aircraft Structures” is to systematically compile the results obtained on a study of four different materials with the objective of establishing and finalizing the failure criteria and putting forth the performance measures that need to be taken for joints. The Strain Concentration Factors (SCF ‘K’) were developed and used to predict the failure loads in a stack-up skin-stringer combination. Subsequent to mechanical testing, failure criteria were developed and other meaningful conclusions to assist the project sponsor (the Aluminum Company of America: ALCOA) with plans related to the testing of aluminum alloys for use in airframe applications. Uniaxial tension tests were conducted over a range of size and configuration of the alloy specimens with the purpose of comparing the strain concentration factor values. The measured sizes included specimens having thicknesses of 0.25 inch and 0.40 inch and widths of 2 inch and 4 inch. For the specimens measuring 2 inch in width, threaded fasteners were used to create filled hole tests, which simulate interference in the holes. Four different aluminum alloys were chosen and tested in uniaxial tension. These are 2026-T3511, C433-T351, C460-T8E67, and 7085-T7651. From the results obtained the following conclusions are drawn. (i) Increasing the width of the test specimen increased the value of strain concentration factor. (ii) In comparing the ‘open hole’ condition with the ‘closed hole’ condition, the presence of fasteners increases the value of strain concentration factor. (iii) In evaluating the intrinsic influence of specimen thickness the 0.25” thick specimen yielded a higher stress concentration value while the 0.40” thick specimen yields a noticeably lower value of the strain concentration factor. (iv) The strain concentration factor at the maximum load yields a lower value than the strain concentration factor at the failure strain. With the K-values established through experimental testing, prediction stack-up methods were used to help predict the failure loads in skin-stringer stack-up combinations. From the experimental results, it is seen that the K-values determined for the 0.40” thickness specimen at the maximum load yielded the most accurate value of the predicted failure loads. Scanning electron microscopy observations were used to characterize the intrinsic features on the fracture surface of the deformed and failed specimens. Precise finite element stress analysis was used to compare analytical results with the experimental finding and observations.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor dc:publisher
- University of Akron
- Year dc:date
- 2006
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Lam, Daniel F.
- Contributors dc:contributor
-
- Menzemer, Craig
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=akron1145393262