Back to search

University of Akron

Computational Fluid Dynamics Analysis of a Prototypic, Prosthetic Venous Valve

Abstract

dc:description

Chronic venous stasis is a disease condition resulting from valvular incompetence caused by either thrombophlebitis or congenital valvular abnormalities. This is a major concern today affecting as many as twenty four million people. While it is usually managed by nonoperative methods, the severity of the disease in some cases demands the exploration of other means of treating this condition. Hence, replacement of damaged venous valves by prosthetic ones is an option that is being pursued. If successful, a prosthetic valve would help to restore the function of the damaged native venous valves. The goal of the current project was to validate the design of a venous valve previously designed (US Patent Application # 11/ 282,515) using a Computational Fluid Dynamics (CFD) simulation. This simulation would help determine parameters which could not be obtained by in-vitro flow modeling and quantify the fluid-solid interactions at a higher resolution than is possible experimentally. Several fluid dynamics parameters were obtained under both steady state (forward and reverse directions) and pulsatile conditions at mean velocities of 0.05 and 0.1 m/s. These approximated conditions seen under resting supine and walking conditions. Parameters obtained were the pressure distribution, velocity profiles, and shear stresses around the valve, and the residence time of the fluid within the valve and behind the leaflets. The velocity profiles gave an insight into the flow patterns within and around the valve and parameters such as the opening and closing torques, accelerations, and impact forces acting to open and close the leaflets as well as the valve resistances were calculated from the pressures. Analysis of the results revealed that the shear stresses are not likely to cause hemolysis. The highest residence times were observed in the sheltered regions just behind the leaflets in all cases but especially for the forward flow condition with average inlet velocity of 0.05 m/s, indicating the potential for thrombus formation in those areas.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Raja, Vidya
Advisor dc:contributor.advisor
  • Rittgers, Stanley

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Raja, Vidya. Computational Fluid Dynamics Analysis of a Prototypic, Prosthetic Venous Valve. masters thesis, University of Akron, 2007. http://rave.ohiolink.edu/etdc/view?acc_num=akron1186686575