University of Akron
Computational Fluid Dynamics Analysis of a Prototypic, Prosthetic Venous Valve
Abstract
dc:descriptionChronic venous stasis is a disease condition resulting from valvular incompetence caused by either thrombophlebitis or congenital valvular abnormalities. This is a major concern today affecting as many as twenty four million people. While it is usually managed by nonoperative methods, the severity of the disease in some cases demands the exploration of other means of treating this condition. Hence, replacement of damaged venous valves by prosthetic ones is an option that is being pursued. If successful, a prosthetic valve would help to restore the function of the damaged native venous valves. The goal of the current project was to validate the design of a venous valve previously designed (US Patent Application # 11/ 282,515) using a Computational Fluid Dynamics (CFD) simulation. This simulation would help determine parameters which could not be obtained by in-vitro flow modeling and quantify the fluid-solid interactions at a higher resolution than is possible experimentally. Several fluid dynamics parameters were obtained under both steady state (forward and reverse directions) and pulsatile conditions at mean velocities of 0.05 and 0.1 m/s. These approximated conditions seen under resting supine and walking conditions. Parameters obtained were the pressure distribution, velocity profiles, and shear stresses around the valve, and the residence time of the fluid within the valve and behind the leaflets. The velocity profiles gave an insight into the flow patterns within and around the valve and parameters such as the opening and closing torques, accelerations, and impact forces acting to open and close the leaflets as well as the valve resistances were calculated from the pressures. Analysis of the results revealed that the shear stresses are not likely to cause hemolysis. The highest residence times were observed in the sheltered regions just behind the leaflets in all cases but especially for the forward flow condition with average inlet velocity of 0.05 m/s, indicating the potential for thrombus formation in those areas.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Engineering
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- University of Akron
- Year dc:date
- 2007
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Raja, Vidya
- Advisor dc:contributor.advisor
-
- Rittgers, Stanley
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=akron1186686575