University of Akron
Experimental and Numerical Evaluation of the Pullout Strength of Self-tapping Bone Screws in Normal and Osteoporotic Bone
Abstract
dc:descriptionSelf-tapping cortical screws (STS) are being increasingly used for fracture fixation in metaphyseal region due to their advantage over the other bone screws. The objective of this study was to compare the pullout index and loading energy of the STS inserted in normal and osteoporotic bone blocks. A 3D model of the bone-screw interface was developed to numerically evaluate the effect of bone quality on pullout strength. Previous studies indicated the significance of pilot hole, insertion torque, screw size and cutting flutes in normal bone. This study evaluated their effects in osteoporotic bone model and compared them experimentally and numerically. For the pullout study the screws were divided into five groups each representing a depth of insertion in normal and osteoporotic bones (six screws per group), respectively. The effects of pilot hole size, cutting flutes, manufacturer, material and screw size on the pullout index (PI) were also evaluated in this study by categorizing the screws into different groups (six screws per group). The pullout protocol specified by ASTM F.543-02 standard for metallic screws was experimentally implemented on a sample size determined by power analysis. Synthetic bone models were used for experimental evaluation. ANOVA was used to statistically analyze the effect of screw size and cutting flutes on the pullout strength. Experimental values indicated that the PI of screws inserted into normal bone blocks was significantly different (p< 0.05) from that of osteoporotic bone blocks. The results also demonstrated that the PI of the screws increased with the depth of insertion in both normal and osteoporotic bones. The performance of stainless steel screws was observed to be significantly different from that of titanium screws in osteoporotic bone but not in normal bone blocks. It was also observed that there was no significant difference in PI and loading energy (LE) for screws from different manufacturers in normal and osteoporotic bone. A finite element model, with non-linear material properties, was analyzed to investigate the interaction of the bone quality and depth of insertion on the pullout characteristics. Bone quality was observed to have a significant effect on the PI as in the experimental testing. The model was validated with the experimental data for the effect of depth of insertion on the PI for normal and osteoporotic bones.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- University of Akron
- Year dc:date
- 2007
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Battula, Suneel Ranga Sai
- Advisor dc:contributor.advisor
-
- Njus, Glen
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=akron1194988102