Back to search

University of Akron

Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging

Abstract

dc:description

Pediatric MR imaging currently uses adult RF coils which reduces the quality of pediatric images considering the large field of view and low signal to noise ratio (SNR). Thus there is a growing need for developing and evaluating specialty coils targeting pediatric patients. The current study focused on the design, development and evaluation of infant cardiac array RF local coil for magnetic resonance imaging of the heart of infant patients. The design criteria were identified and the coil was designed taking into account the safety considerations for the targeted patient population. This study successfully evaluated the performance of the infant cardiac array RF coil based on two most significant MR imaging parameters, SNR and imaging resolution, on a 1.5T commercial MR scanner. The increase in SNR and improvement in the resolution of images using the infant cardiac array over an existing commercially available adult coil was establishedusing different kinds of phantom (7L, 2L, orange and lime) studies. The results revealed that there was an increase of 140% in SNR using infant cardiac array compared to the commercially available adult coil and the high resolution (<200 microns) images obtained confirmed the efficacy of the infant cardiac array coil. Thus, the infant cardiac array RF coil provides enhanced performance and high quality MR images for infant clinical applications compared to the commercial adult coils.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ravi, Anandh
Advisors dc:contributor.advisor
  • Reddy, Narender P.
  • Sheffer, Daniel B.

Subjects

dc:subject × 11

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Ravi, Anandh. Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging. masters thesis, University of Akron, 2008. http://rave.ohiolink.edu/etdc/view?acc_num=akron1226615129