Back to search

University of Akron

A Novel Technique to Improve the Resolution and Contrast of Planar Nuclear Medicine Imaging

Abstract

dc:description

Nuclear medicine images have limited spatial resolution because of the limitations in the radiation detector and the associated electronics. Due to these limitations, the image of a point source of radiation is blurred. The degree of this blurring is called the point spread function of a gamma camera, the imaging device used in nuclear medicine. The aim of this study is to evaluate a technique to increase the spatial resolution and contrast by improving the point spread function of the system. The basic idea of the proposed technique is to restrict radiation so that overlapping point spreads due to adjacent point sources could be isolated. This was achieved by using a special lead mask, having a particular pattern of apertures, with the existing technique. The new technique was implemented in two variations by using special lead masks with different sizes, shapes and patterns of apertures in order to investigate the degree of improvement in the spatial resolution. The images obtained with the proposed technique were compared to those obtained with the conventional technique. Qualitative comparisons were made by visually inspecting the images obtained by the two techniques while quantitative comparisons were made by statistically testing their modulation transfer functions for significant differences. Both the comparisons indicated that the proposed technique was successful and gave images with increased spatial resolution and contrast.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Raichur, Rohan
Advisors dc:contributor.advisor
  • Mugler, Dale
  • Passalaqua, Anthony

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Raichur, Rohan. A Novel Technique to Improve the Resolution and Contrast of Planar Nuclear Medicine Imaging. masters thesis, University of Akron, 2008. http://rave.ohiolink.edu/etdc/view?acc_num=akron1226955205