Back to search

University of Akron

Simulation of a Complete Cardiovascular Loop: Development of a Simulink Based Pressure-Flow Model to Obtain the Origin of the Electrical Impedance Cardiogram

Abstract

dc:description

Impedance cardiography is a non-invasive measurement method to determine cardiac output and stroke volume. The reason behind this method’s lack of popularity for clinical purposes is a dearth of understanding about the factors contributing to the origin of impedance cardiogram. Variations in instantaneous volumes form the thoracic cavity contribute to the change in impedance curve, and in the past several simulations were performed based on this concept. In the present study, a lumped parameter model of a multi-loop circulatory system was developed using Simulink®. The model outputs were flow/pressure waveforms, which exhibit a similarity with physiological curves. The impedance cardiogram was determined by a first-order derivative of a weighted sum of instantaneous thoracic volumes. With correctly adjusted lumped volumes, it was assumed that the signal obtained from the model would be analogous to the dz/dt curve. The volumes were adjusted through variable gain amplifiers incorporated in the model and adjusted by the Simulink Response Optimization Toolbox ® routine of Matlab®. The optimization process tuned the gains to minimize the differences between the simulated and reference waveform. This process was carried out for different combinations of the volumes to obtain the most morphologically similar waveform. The results suggest that the impedance cardiogram waveform is related to volume changes in the thoracic vena cava, abdominal vena cava and ascending aorta.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Trivedi, Dyuti Kishorbhai
Advisor dc:contributor.advisor
  • Taylor, Bruce C.

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Trivedi, Dyuti Kishorbhai. Simulation of a Complete Cardiovascular Loop: Development of a Simulink Based Pressure-Flow Model to Obtain the Origin of the Electrical Impedance Cardiogram. masters thesis, University of Akron, 2009. http://rave.ohiolink.edu/etdc/view?acc_num=akron1232729044