Back to search

University of Akron

Biocompatibility of Polymer Implants for Medical Applications

Abstract

dc:description

<p>Two separate experiments were performed to test the biocompatibility of amphiphilic conetwork polymers for medical applications. In experiment 1, four different types of polymers were tested in the liver and brain of 20 rats to determine which polymer would be best suited for intervertebral disc repair or replacement. The samples used for the brain and liver injections were Monomer: 1-cyanoacryl-2,4,4-trimethylpentane(TMP-CA), Polymer: cyanoacrylate terminated tri-arm star PIB [Ø(PIB-CA)3, Initiator: N,N-diethyl telechelic [Ø(PIB-NEt3)3] PIB, and Monomer + Polymer Combination: cyanoacrylate-telechelic 3-arm star polyisobutylene [Ø(PIB-CA)3] + 2,2,4-trimethylpent-1-cyanoacrylate (pTMP-CA). The solid samples implanted into the liver were Monomer: poly(1-cyanoacryl-2,4,4-trimethylpentane)poly(TMP-CA), Polymer: cross linked [Ø(PIB-CA)3] polymer, and Monomer + Polymer Combination: copolymer of [Ø(PIB-CA)3] + 2,2,4-trimethylpent-1-cyanoacrylate (pTMP-CA).</p><p>The rats were divided into three groups. Group number one had four different “honey-consistency” gel polymers injected into the liver and a saline injection for control. Group number two was subjected to the same injections, but this time the site of injection was the brain. Group number three had three types of solid polymers surgically implanted into the liver. Tissues were then examined histologically to determine if any damage had occurred. A polymer sample that resulted in little or no significant tissue damage would be a good candidate for intervertebral disc replacement and/or repair.</p><p>In experiment 2, two types of polymers were used; a polyisobutylene polymer as well as a Bionate sample for a control, (to determine the biocompatibility of the polymer for a potential pacemaker coating). Both were implanted on the peritoneal wall of eight rats. The rats were divided into two groups of four. Group number one had four polyisobutylene polymer strips sutured to the peritoneal wall. Group number two had four Bionate strips also implanted on the peritoneal wall. Tissue at the implant site was removed and examined histologically to determine if any damage had occurred. A polymer sample that resulted in little or no significant tissue damage was considered a good candidate for a potential pacemaker coating.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biology
Grantor dc:publisher
University of Akron
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Brendel, Christopher M.
Contributors dc:contributor
  • Ely, Daniel

Subjects

dc:subject × 17

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Brendel, Christopher M.. Biocompatibility of Polymer Implants for Medical Applications. masters thesis, University of Akron, 2009. http://rave.ohiolink.edu/etdc/view?acc_num=akron1246892895