A Study of Impedance to Cerebrospinal Fluid Flow in Type I Chiari Malformation

Abstract

dc:description

<p>Type I Chiari Malformation (CMI) is a complex disorder of the craniospinal system classically characterized by herniation of the cerebellar tonsils of 3-5 mm past the foramen magnum. CMI has proven difficult to diagnose and often takes years to identify, as the associated neurological symptoms may overlap with the symptomatology of other disorders. Current methods of quantifying the severity of CMI, such as cerebellar tonsil herniation depth and reduced posterior cranial fossavolume, do not necessarily correlate with symptom severity. Likewise, studies that have sought to hydrodynamically characterize CMI by examining cerebrospinal fluid (CSF)velocities have yielded mixed results. Hence, there exists a need for a quantitative diagnostic measurement of CMI severity which better correlates to neurological symptomatology.</p><p>Longitudinal impedance (LI), a hydrodynamic parameter which is a function of conduit geometry, has been shown to correlate with long-term patency in vein grafts. LI has been noted as particularly suited to long, rigid, unbranched conduits with highpressure flow patterns that follow the cardiac cycle. As such, it may be useful in characterizing the state of a spinal canal affected by CMI by quantifying the blockage in the spinal canal created by cerebellar tonsil herniation.</p><p>In this study, models of the cervical spinal canal were reconstructed from MR images, computational fluid dynamics (CFD) techniques were used to simulate CSF flow in each model, and longitudinal impedance was computed during one flow cycle.Integrated LI (impedance to the components of unsteady flow between 1 and 8 Hz) was calculated for a variety of different inlet velocity boundary conditions in an example cervical SAS and shown to vary only slightly (<2%), demonstrating that good estimates of patient specific LI could be obtained without a subject-specific CSF flow waveform.Integrated LI was then calculated in 4 volunteer cases, 12 asymptomatic CMI cases, 2 asymptomatic CMI cases, and 2 equivocal cases. Median values of integrated LI for volunteers, asymptomatic CMI patients, symptomatic CMI patients, and equivocalpatients were 205, 388, 830, and 395 dynes/cm5, respectively. A significant difference in median integrated LI between groups was demonstrated using one-way analysis of variance by ranks. Additionally, integrated LI was shown to increase with a reduction in the volume of fluid space in the cervical SAS, as expected. However, geometries with similar cervical SAS volume were still shown to have different integrated LI depending on the complexity of the conduit geometry.</p><p>The methodology used in this study provides a basis for the use of computational simulations of CSF flow to hydrodynamically analyze the state of the spinal canal. This methodology may have potential to objectively quantify CMI severity and achieve thelong-term research goal of assisting in surgical planning for CMI patients, but would require a larger number of patients.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shaffer, Nicholas
Advisor dc:contributor.advisor
  • Loth, Francis

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Shaffer, Nicholas. A Study of Impedance to Cerebrospinal Fluid Flow in Type I Chiari Malformation. masters thesis, University of Akron, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=akron1301674180