Back to search

University of Akron

A Study of Sensitivity Mapping Techniques for Multi-Channel MR Coils

Abstract

dc:description

Radio Frequency (RF) Coil technology has been rapidly growing hand in hand with Magnetic Resonance Imaging (MRI) technology to complement one another to provide the highest level improvements to patient screening. The technical innovations for MRI machines are based on marketing requirements that are driven by the inputs provided by clinical radiologists. Therefore, the job of the RF coil engineers is to design coils in such a manner that the coils meet the MRI product specifications. While keeping this in mind, the RF coil engineers use proven techniques or develop new techniques to save time in test & measurement, reduce cost in material and maximize results with the strong support of data. The sensitivity profile of the RF Coil is determined by its geometry and physical size. Therefore, the field of view (FOV) of the image is partial to the sensitivity of the coil. If the RF coil is a large size that can cover a large image anatomy, this coil would have a large spatial coverage but would receive more noise than a smaller RF coil that would cover a smaller image anatomy. Presently, the sensitivity measurements are performed with the help of sensitivity Probes and Network Analyzers during RF coil construction. However, these test results do not completely measure the uniformity of the coil product. To further examine the uniformity, the coil needs to be tested with an MRI system. The test results using various techniques during MRI scan with loaded and unloaded phantoms, confirm the further needs of adjustments. However, the techniques sometimes have limitations due to complexity and/or the lack of resource and MRI system availability. Therefore, saving time in test & measurement and maximizing the support of the data may possibly make the sensitivity mapping technique an ideal scenario. A sensitivity mapping technique for Multi-Channel MR coils was developed to provide a simpler and repeatable method to collect data in order to understand the uniformity of MRI coil products. A circularly polarized quadrature probe was designed with a 90-degree combiner and tuned to Larmor frequency for 1H when present in a constant 3.0 T magnetic field in order to facilitate accurate measurement. This device can be tuned to other frequencies for other MR applications. In order to be able to derive the sensitivity mapping inside of the coil, the quadrature probe was positioned in various locations within the coil sensitivity volume to collect the sensitivity data.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dalveren, Taylan
Contributors dc:contributor
  • Ida, Nathan

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Dalveren, Taylan. A Study of Sensitivity Mapping Techniques for Multi-Channel MR Coils. masters thesis, University of Akron, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=akron1373403690