dc:descriptionThe power quality of microgrids is one of the major issues in determining whether the microgrid is operating in grid connected (GC) mode or standalone (SA) mode. Power quality is degraded by harmonics, voltage unbalance, voltage sag and voltage swells. Harmonics cause performance degradation, aging, equipment heating and severe problems for critical loads that require very high power quality. In order to ensure the power quality of the grid and meet the standards, both active and passive power compensators are used. Due to the change in the coupling and inverter filter impedances in the microgrid, harmonics are not shared equally by the individual compensators. So, a particular inverter may be overstressed with the harmonic compensation operation. If the inverters in a decentralized microgrid structure are not adaptive, the system may be unstable due to inverter overloading.A novel adaptive harmonic compensation method for decentralized islanded microgrid structures is presented that incorporates the effect of line impedance parameter changes. The system can provide better harmonics sharing without any communication among the inverters or the central unit. For low harmonic current, the adaptive compensation system prioritizes voltage regulation at a Point of Common Coupling (PCC).For the GC mode of microgrid operation, the strategy to eliminate harmonics from the grid current as well as the PCC voltage for microgrid applications are presented in this dissertation. The position of the harmonics reduction unit is selected so that it can reduce the harmonic level of the grid current and PCC voltage harmonics irrespective of the distribution of the renewable energy sources in the microgrid. In the proposed control algorithm, the required amount of attenuation for the harmonics is determined to meet the THD requirement. A fast and efficient algorithm for phase detection irrespective of the presence of harmonics is used for the system. The effect of interharmonics and other disturbances on the phase detection system are presented. The role of a smart load in harmonic compensation is introduced through a dual boost PFC rectifier topology for input stage harmonic compensation. The effectiveness and performance of proposed methods are verified through simulations and experimental tests.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Engineering
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Electrical Engineering
- Grantor dc:publisher
- University of Akron
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Anwar, Saeed
- Contributors dc:contributor
-
- Sozer, Yilmaz
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=akron1406653103