University of Akron
Characterization of Transition to Turbulence for Blood in an Eccentric Stenosis Under Steady Flow Conditions
Abstract
dc:descriptionBlood is a complex fluid that consists of approximately 45% solid particulates by volume. These solid particulates, erythrocytes, cause the fluid to exhibit a non-Newtonian, shear thinning rheology under low shear rates (<200s-1) and Newtonian rheology otherwise. Many researchers employ Newtonian blood analogs to study the relationship between hemodynamics and morphogenesis when the predominant shear rates in the vessel are high. Non-biological, shear thinning fluids have been observed to transition from laminar to turbulent flow differently than Newtonian fluids. A discrepancy between the critical Reynolds number of blood and a Newtonian analog could result in erroneous predictions of hemodynamic forces. The goal of the present study was to compare velocity profiles near transition to turbulence of whole blood and a Newtonian blood analog downstream of a stenosis under steady flow conditions. Doppler ultrasound was used to measure velocity profiles of whole porcine blood and a Newtonian fluid in an in vitro experiment at 13 different Reynolds numbers ranging from 150 to 1200. Three samples of each fluid were examined and fluid rheology was measured before and after each experiment. Results show parabolic like velocity profiles for both whole blood and the Newtonian fluid at Reynolds numbers less than 250 (based on the viscosity at 400s-1). The Newtonian fluid had blunt velocity profiles with large velocity fluctuations (root mean square as high as 25%) starting at Reynolds numbers ~250 which indicated transition to turbulence. In contrast, whole blood did not transition to turbulence until a Reynolds number of ~300-600. All three blood samples were delayed compared to that of the Newtonian fluid, although there were variabilities between the critical Reynolds numbers. For Reynolds numbers larger than 700, the delay in transition resulted in differences in velocity profiles between the two fluids as high as 35%. A Newtonian assumption for blood at flow conditions near transition can lead to large errors in velocity prediction for steady flow in a poststenotic flow field. Since this study was limited to a single velocity profile, further studies are required to fully understand the post-stenotic flow field. Further research is necessary to understand the importance of pulsatile flow and compliance.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Engineering
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor dc:publisher
- University of Akron
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Casey, David Michael
- Advisor dc:contributor.advisor
-
- Loth, Francis
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=akron1418066674