University of Akron
Surface Modifications of Orthopedic Implants for Improved Performance
Abstract
dc:descriptionOrthopedic implants are used as medical devices that are surgically implementedinto the body and designed to replace a missing joint, a bone or to support a damagedstructure. Even though orthopedic implants have excellent outcomes such as restoringmobility and increasing the quality of lives, the failure of these implants occasionallytakes place. This thesis examines a process called “superfinishing” as an alternativesurface modification method for use on orthopedic implants that may yield better patientoutcomes. It is believed that superfinishing may improve desired properties such asbending stress, fatigue strength, resistance to bacteria adhesion, wear resistance, chemicalinertness, low coefficient of friction, and similar or better adhesion characteristics thanstainless steels/titanium. The focus of this thesis is to show improvement in bendingstrength. In this study, specimens were superfinished in two different types of abrasives:aluminum oxide (Al3O2) and silicon carbide (SiC). The results demonstrated thatroughness value of stainless steel rods in Al2O3 powder/walnut shell mix decreased to0.156µm from 0.221µm and roughness value of stainless steel rods in SC powder/walnutshell mix decreased to 0.100µm from 0.184µm which is 36-44% decrease in roughnessvalue. The experiment indicated that roughness value of these rods becomes stable after21 minutes of superfinishing process but the maximum average load results werecollected after 9 minutes of superfinishing process. This study showed that the longer superfinishing process does not necessarily increase the bending strength. This studyalso showed that the bending strength of superfinished Ti-6Al-4V rods was increased by3.81% with SiC abrasives. In addition, bending strength of superfinished 316L rods wereincreased by 3.35% in Al3O2 abrasives and by 6.49% in SiC abrasives after 9 minutes ofsuperfinishing process. Residual stresses should be studied as the future work to grasp theeffects of superfinishing process.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Engineering
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- University of Akron
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Cipa, Esra
- Advisor dc:contributor.advisor
-
- Mahajan, Ajay
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=akron1454680174