Back to search

University of Akron

Feedback Control for Maximizing Combustion Efficiency of a Combustion Burner System

Abstract

dc:description

An observer-controller pair was designed to regulate the fuel flow rate and the flue-gas oxygen ratio of a combustion boiler. The structure of the observer was a proportional-integral state estimator. The designed controller was composed of a combination of two common controller structures: state-feedback with reference tracking and proportional-integral-derivative(PID).A discrete-time, linear state-space model of the combustion system was developed such that the linear controller and observer could be designed. This required establishing separate models pertaining to the combustion process, actuators, and sensors. The complete model of the combustion system incorporated all three models. The combustion model, which related the flue-gas oxygen ratio to the fuel and oxygen flow rates, was obtained using the mathematical formulas corresponding to combustion of natural gas. The actuators were modeled using measured fuel and oxygen flow rate data for various actuator signals, and fitting the data to a parametric model. The established nonlinear models for the combustion process and actuators required linearization about a specified operating point. The sensors model was then obtained using the predictive error identification technique based on batch input-output data.For the acquired model of the combustion system, a linear quadratic regulator was used to calculate the optimal state feedback gain. The classical controller gains were determined by tuning the gains and evaluating the simulation of the closed-loop response. Computer-aided simulations provided evidence that the controller and state estimator could regulate the desired set point in the presence of moderate disturbances. The observer-controller pair was implemented and verified on an experimental boiler system by means of an embedded system. Even in the presence of a disturbance resulting from a 50% blockage of the surface area of the air intake duct, the closed-loop system was capable of regulating the desired set point for slow-varying reference signal changes.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Horning, Marcus
Contributors dc:contributor
  • Ida, Nathan

Subjects

dc:subject × 10

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Horning, Marcus. Feedback Control for Maximizing Combustion Efficiency of a Combustion Burner System. masters thesis, University of Akron, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=akron1459356183