Back to search

University of Akron

Direct Power Control of a Doubly Fed Induction Generator in Wind Power Systems

Abstract

dc:description

The doubly fed induction generator (DFIG), due to its improved dynamic behavior, reduction of mechanical stress on wind turbine (WT) and the increase of power capture, is the most popular for large scale wind energy generation systems. Since DFIG is a wound rotor induction machine, most well-known schemes for induction motor drives such as field oriented control (FOC), and direct torque control (DTC) are applicable for controlling the generator in a DFIG-based wind energy system. This dissertation presents the analysis, modeling, simulation and implementation of a direct power control (DPC) for a doubly fed induction generator (DFIG) based wind energy system. Both theoretical and practical aspects of non-linearity behavior of the hysteresis-based controller (HBC) in DPC during grid-connected (GC) modes are investigated. Viability of DPC approach with hysteresis-based controller for stand-alone (SA) mode and transition from SA to GC of DFIG-based wind energy system is also analyzed. Two major drawbacks of HBC on DPC drive, namely high active and reactive power ripples and variable switching frequency of the rotor side converter were studied. In order to address these problems, this dissertation proposed a pair of active and reactive power controllers to replace the hysteresis-based controllers. The active power controller proposed in this thesis consists of a proportional-integrator (PI) controller, two triangular carrier generators and a pair of comparators that produce a three-level output, namely –1, 0, and 1. The proposed reactive power controller is similar to the active power controller and consists of a proportional controller, a single triangular carrier generator and a two-level comparator whose output is switched between 1 and 0. The HBC and proposed controllers are applied to the DPC drive in grid-connected and stand-alone modes are analyzed, simulated and implemented. The results of the simulation and experiment are discussed and compared. The transition between stand-alone and grid connected modes included synchronization are analyzed and discussed. The proposed algorithm for transition between SA and GC provided a smooth active and reactive power flow to the islanded-loads. The design and implementation of the laboratory set-up consisted of 7.5 HP wound rotor induction generator as wind generator and a 10 HP induction motor as wind turbine emulator. A fixed-point TI microprocessor (TMS320F2812) is used for controlling the rotor side converter and to convert the analog voltages and currents to digital data. The experimental results are presented, discussed and compared with those of the simulation. The future work proposed in this dissertation consists of a DPC for an unbalanced grid voltage and non-linear islanded loads. Since the experimental set-up is presented future wind research, can be implemented by changing the control algorithm.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
University of Akron
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sam, Mahmodicherati
Advisor dc:contributor.advisor
  • Elbuluk, Malik

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Sam, Mahmodicherati. Direct Power Control of a Doubly Fed Induction Generator in Wind Power Systems. doctoral thesis, University of Akron, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=akron1470315542