Case Western Reserve University School of Graduate Studies
Spatially selective activation of peripheral nerve for neuroprosthetic applications
Abstract
dc:descriptionThe goal of this work was to develop electrodes and stimulation techniques that enable selective electrical excitation of discrete populations of peripheral nerve fibers within a peripheral nerve trunk. A nerve cuff electrode containing 12 individually addressable electrode contacts was tested in acute and chronic experiments on cat sciatic nerve. The forces developed in the ankle musculature were recorded either directly or by measurement of the ankle joint torque. Four distinct strategies to achieve selectivity were investigated: Electrode Geometry: spatially distributed electrode contacts generated localized patterns of excitation within the nerve trunk, Field Steering: sub-threshold currents applied from other electrode contacts coincident with the stimulus pulse modified the region of excitation, Stimulus Duration: different stimulus pulsewidths were tested for selectivity, and Manipulation of Membrane Excitability: the non-linear sodium conductance of the nerve membrane was controlled to invert the current-distance relationship. Using tripolar electrode geometries and field steering currents it was possible to achieve selective and graded activation of individual fascicles within the nerve trunk. Selectivity was dependent on the relative positions of the electrode contacts and nerve fascicles, and the spacing between neighboring fascicles. Selectivity between fascicles was increased when using short duration stimuli as compared to longer duration stimuli. Use of field steering current increased selectivity by restricting excitation to a more localized region of the nerve trunk in both acute and chronic implants. Measurements with chronically implanted electrode yielded recruitment properties that were independent of joint position. Recruitment properties were less variable between 8 weeks and 24 weeks after implant than between 1 week and 8 weeks after implant. These results indicated that the cuff enabled selective activation on a long-term basis, and that connective tissue encapsulation stabilized the electrode. A sub-threshold depolarizing pre-pulse was used to invert the classic current-distance relationship. This allowed selective activation of nerve fibers more distant from the electrode with lower currents than required to excite nerve fibers close to the electrode
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 1995
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Grill, Warren Murray, Jr.
- Contributors dc:contributor
-
- Mortimer, J.
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1058537999