Case Western Reserve University School of Graduate Studies
Optimization and automation of stimulus map synthesis for upper extremity FNS
Abstract
dc:descriptionFunctional neuromuscular stimulation (FNS) has been used to power an open-loop upper extremity neuroprosthesis. A principle issue in the implementation of the neuroprosthesis is the synthesis of the stimulus map, which relates the input control signal to the output stimulus level applied to each electrode. The goal of this project was to develop a method for synthesizing the optimum stimulus map, which is defined as the stimulus map for which the resulting grasp output most closely matches the desired grasp output. Optimization is achieved by (1) compensating for the influence of the electrode-position dependent recruitment properties on the grasp output, and (2) minimizing the influence of the time and task dependent variables on the grasp output. The time and task dependent variables are fatigue, object size and extremity position. Compensation for the position dependent recruitment properties was achieved by the development of an external moment grasp synthesis procedure (EMGSP) for stimulus map synthesis. The EMGSP describes the interaction between the active moments produced by electrical stimulation, the passive joint moments, and the resulting total joint moment and angle. The EMGSP was used to develop the stimulus map for three paralyzed subjects, and in all cases the EMGSP-generated grasp had lower errors than grasp patter ns developed using the previously implemented rule-based method of stimulus map synthesis. The EMGSP was successful in compensating for the influence of the position dependent recruitment properties on the grasp pinch force Minimization of the influence of the time and task dependent variables on the grasp output was accomplished using a simulation of the EMGSP. The results indicate that proper selection of the assumed contact point and minimization of cocontraction reduces the grasp output error. Further improvement in grasp output can be obtained by rejecting electrodes with high gain, thumb flexor electrodes with positive output stiffness (flexion force increases as thumb is extended) and thumb extensor electrodes with negative output stiffness. The outcome of this project is a method for optimizing and automating the synthesis of the stimulus map used in open loop upper extremity FNS
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 1991
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kilgore, Kevin Lloyd
- Contributors dc:contributor
-
- Peckham, P.
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1059576993