Case Western Reserve University School of Graduate Studies
Electrical activation of the diaphragm using epimysial electrodes
Abstract
dc:descriptionThe goal of this research was to test epimysial electrodes for electrical activation of the diaphragm (diaphragm pacing) for ventilatory assist. Epimysial electrodes were applied to diaphragm pacing to alleviate risk of phrenic nerve damage associated with cuff electrodes and placement difficulties associated with intramuscular electrodes. Epimysial electrodes were stapled onto the abdominal surface of the canine diaphragm within 1.4 cm of the phrenic nerve motor point using a laparoscopic surgery and test stimulation of many potential implant sites. Improvements in electrode placement to within 0.5 cm of the motor point were developed using recruitment curve measurements and retrospective laparoscopic image data to locate the motor point. An Endopath laparoscopic stapler and an electrode thickness between 0.75 mm and 1.0 mm enabled attachment of epimysial electrodes to the diaphragm with low risk of muscle perforation. An impedance pneumograph using the implanted electrodes was effective for detecting breathing events during diaphragm pacing and the feasibility for detection of airway obstruction and calibration of tidal volume was demonstrated. Full activation of the diaphragm was achieved with electrodes placed within 1.0 cm of the phrenic nerve motor point. Muscle length d ependent recruitment was documented and correlated with electrode location relative to the motor point and the longitudinal muscle fiber direction. The long term recruitment improvements were documented in 21 of 32 implanted electrodes. Optimal stimulus parameters that minimize the risk of diaphragm fatigue while maintaining a minimum level of ventilation were found using the surrogate worth trade-off method. We found that similar risks of fatigue occur for a 14 Hz change in stimulation frequency and 0.1 change in duty cycle based on 30 minute recordings of tidal volume during diaphragm pacing. Histological results from the long term implants showed an active chronic tissue reaction consistent with mechanical stresses placed on the tissue near the electrodes. Capsule thicknesses after 3 months averaged 1.24 mm and the risk of continued capsule growth prevented recommendation of clinical application of this electrode design
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 1995
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Schmit, Brian David
- Contributors dc:contributor
-
- Mortimer, J.
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1062594358