Case Western Reserve University School of Graduate Studies
FRP Reinforced Concrete and Its Application in Bridge Slab Design
Abstract
dc:descriptionFor decades, bridge slabs have been troubled by the corrosion of steel reinforcements. The unique corrosion resistance of FRP (Fiber-Reinforced Polymers) bars makes them a promising alternative to steel bars. Because of the relatively low elastic modulus of FRP reinforcement, the post-cracking serviceability often is the controlling factor in the flexural design of FRP reinforced concrete. Since bridge deck slabs are under repeated traffic loads, it is the post-cracking serviceability under cyclic loads that becomes vital in the design and maintenance decision-making process. Experiments have been conducted to investigate the post-cracking flexural performance of FRP RC (reinforced concrete) under constant amplitude cyclic loading. Each specimen tested was a beam with a single FRP bar at the bottom. Two different types of FRP bars were used. The crack opening was monitored for specimens of different size. Up to 2 million cycles of cyclic loads have been applied at 100% service load levels. It has been found that there are two stages in the crack growth of FRP reinforced concrete. The first stage is early growth, which is characterized by increasing crack mouth opening displacement (CMOD). The second stage is the stabilization of CMOD and crack length. No fatigue failure was encountered in the testing under service loading and moderate overloads. The effects of moderate overload on observed crack growth were also investigated. The performances of two different FRP bars were compared. A model was proposed to predict long term crack growth in FRP R/C under cyclic loading, based on the Paris equation. Two FE (finite element) crack representations were examined. One was a debonded length representation. In this model it was assumed that there was a debonded length around each crack, within which there was no tangential interaction between concrete and reinforcement. Beyond the debonded length, the interface between concrete and reinforcement was tied with no relative movement. The other representation examined was a fictitious material crack representation. A fictitious material was placed in a triangular crack cross section, with a maximum width of 2.5mm (0.1 in). Then, the modulus of elasticity of the fictitious material was calibrated, based on the observed testing results, after crack growth had stabilized. Both representations have been used to analyze bridge slabs. Finally, an empirical slab design was discussed.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Civil Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zou, Yunyi
- Contributors dc:contributor
-
- Huckelbridge, Arthur
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1101960743