CHARACTERIZATION OF ATHEROSCLEROSIS WITH MAGNETIC RESONANCE IMAGING, CHALLENGES AND VALIDATION

Abstract

dc:description

The long-term goal of this research is the characterization of atherosclerosis lesions in vivo using Magnetic Resonance Imaging (MRI). Our particular interest is the computer-aided diagnosis and staging of the disease, especially the detection of vulnerable plaques. Multi-contrast MRI scans are used (e.g. PDW, T1W, and T2W) to assess the presence and morphology of vessel lesions in human arteries. The first chapter of this thesis reviews the existing techniques for atherosclerosis imaging with emphasis on MRI. The challenges facing intensity-based computer methods are then investigated. The subsequent four chapters address specifically the four main issues that have been identified: 1) Intensity inhomogeneity, which is present when surface coils or intravascular microcoils induce shading artifacts across the data. Artifacts are modeled as a smooth multiplicative bias field with a cubic spline. The cubic spline is optimized to minimize the entropy of the corrected image. Extension to intravascular axial images is presented. 2) Partial volume effect; despite recent improvements in MRI technologies, image resolution is still a limiting factor owing to the small size of the vessel wall and its lesions. A new approach is investigated to address this issue. Under the assumption that homogenous tissues are well separated by an edge, a reverse diffusion model is implemented. Extension to reduce noise is also introduced by using a diffusion coefficient function of the image gradient. 3) Misregistration; Patient and physiological motions induce misregistration between the datasets with different contrast, requiring methods with sub-voxel accuracy to re-align them. The limits of registration methods are investigated and a new constant variance filter is described to improve intensity-based automatic registration accuracy and robustness. This filter removes local maxima and global bias in similarity measures. 4) The last issue investigated is validation; a new method is presented to produce three-dimensional ground truth of ex vivo vessel specimens. This method uses a novel Cryoimaging system where frozen specimens are serially cut and imaged using bright field and fluorescence microscopy. The last chapter discusses potential applications to other diseases and image modalities, future works, and concludes about the perspectives of atherosclerosis imaging with MRI.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Salvado, Olivier
Contributors dc:contributor
  • Wilson, David

Subjects

dc:subject × 12

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Salvado, Olivier. CHARACTERIZATION OF ATHEROSCLEROSIS WITH MAGNETIC RESONANCE IMAGING, CHALLENGES AND VALIDATION. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2006. http://rave.ohiolink.edu/etdc/view?acc_num=case1152214735