Case Western Reserve University School of Graduate Studies
DEVELOPMENT OF DIMETHYL ETHER (DME) AND CARBON DIOXIDE SENSORS USING PLATINUM NANOPARTICLES AND THICK FILM TECHNOLOGY
Abstract
dc:descriptionA three-electrode based voltammetric sensor as a disposable, economical and portable sensing device was designed and fabricated using thick film technology. Without further modification of an electrode, this versatile voltammetric sensor was capable of sensing both Dimethyl Ether (DME) and carbon dioxide (CO2) only by adjusting the operating parameters. The performance can be further enhanced by hand-printed platinum nanoparticles ink onto working electrode surface. A three-fold increase in the signal output of the sensor was obtained from the electrode with the platinum nanoparticle. A DME sensor was proposed as the alternative analytical method for the measurement of mucosal blood flow, replacing the currently used gas chromatography and mass spectroscopy. Owing to the close relationship with the functioning of the respiratory system, the measurement of mucosal blood flow was physiologically and clinically important. Evaluation and characterization of this sensor was carried out over the DME concentration range of 0% v/v to 7% v/v; a linear relationship between sensor output and the DME concentrations existed with an average R2 of 0.996. The sensor reproducibility was very good with the relative standard deviation within 5%. The DME sensor was not significantly affected by the presence of CO2, a possible interference in the exhaled air. The sensing property of the CO2 sensor was explored via an anodic adsorbate stripping where the sensing output was linearly related to the CO2 presented. Optimization for the operating parameters, i.e., gas sample residence time, adsorption time, and adsorption potential for CO2 measurement, were also carried out. The sensor yielded an order of magnitude higher sensitivity than the value reported in literature and its reproducibility was within 5% relative standard deviation. Our studies showed that the non-uniformity of the crystal planes, i.e. some absorption sites that were more active than others, explained the variation of sensitivity to adsorption potential and crystallographic orientation of the platinum electrode. Stability measurement demonstrated that the decline of the active surface area and the sensitivity of the sensor were 8% and 13% over a two week period. The kinetics of CO2 adsorption was modeled under the assumption of a Langmuir adsorption, which the system strictly obeyed at low surface coverage.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Chemical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2007
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Photinon, Kanokorn
- Contributors dc:contributor
-
- Liu, Chung-Chiun
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1164899809