Back to search

Case Western Reserve University School of Graduate Studies

CONTINUOUS SAMPLING IN MAGNETIC RESONANCE IMAGING

Abstract

dc:description

<p>MRI pulse sequences are used to acquire spatial-frequency data (k-space) by using linear magnetic field gradients to encode a k-space trajectory. Common k-space trajectories including rectilinear typically limit sampling to periods of constant gradient amplitude resulting in uniformly-sampled data during the acquisition period. However, these trajectories often do not acquire data during gradient ramp times or during read gradient dephase/rephase lobes. In this work, data acquisition and image reconstruction techniques were developed to improve the effective utilization of these times to improve image quality. Continuous sampling (CS) is defined as data collected anytime after RF excitation.</p> <p>A Cartesian CS acquisition was developed by extending the acquisition window over the entire balanced and isolated read gradient. The gradients were designed to sample each k-space pixel at least twice to essentially accomplish two averages in a single acquisition. Cartesian CS resulted in over 40% improvement in SNR for a true-FISP sequence relative to the traditional Cartesian acquisition in phantom and asymptomatic volunteer imaging studies.</p> <p>Non-Cartesian CS sequences including the BOWTIE trajectory and unequal gradient amplitude CS were developed for faster CS sequences with similar SNR gains. For the unequal gradient amplitude case a range of SNR gain of 19 to 50% was seen. The BOWTIE trajectory was accomplished by overlapping PE and read gradients and resulted in a 35% increase in SNR compared to the traditional Cartesian. Both resulted in a reduction of imaging time at the cost of SNR compared to the original CS sequence.</p> <p>A Cartesian CS Dixon fat/water separation techniques was developed by applying the Dixon echo time variation between CS echoes. The redundant data collected during CS produced two Dixon images in one acquisition. The CS Dixon resulted in equivalent fat suppression in water images in approximately half the time compared to a 2PD acquisition.</p> <p>A novel 2D translational motion artifact correction method was developed that uses phase differences at trajectory intersections. Unlike conventional navigator methods, the described technique allows motion artifact correction with data collected along different trajectories, demonstrated here with the BOWTIE trajectory. Corrections based on simulations and experiments both result in image artifact reduction.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bookwalter, Candice Anne
Contributors dc:contributor
  • Duerk, Jeffrey

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Bookwalter, Candice Anne. CONTINUOUS SAMPLING IN MAGNETIC RESONANCE IMAGING. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2008. http://rave.ohiolink.edu/etdc/view?acc_num=case1194049081