dc:description

<p>This dissertation presents the development of microfabrication processes for the integration of process-incompatible, dissimilar materials in MEMS devices with application to neural interfaces for long-term implantation. Micromachining techniques were developed for a novel, mechanically-dynamic, chemo-responsive polymer nanocomposite based on a poly(vinyl acetate) matrix with embedded cellulose nanofibers designed to address issues related to the mechanical mismatch between the neural probe and cortical tissue. Microtensile testing was performed to assess the mechanical properties of laser-patterned nanocomposite microstructures. Within 3-7 minutes of immersion in DI water, the nanocomposite displayed a reduction in Young’s modulus by a factor of 140-200, from 1.2-3.4 GPa to 4.9-22 MPa, depending upon the cellulose nanofiber source and concentration. A comparable reduction in Young’s modulus was measured for samples that had been implanted in a rat cortex, suggesting this material can penetrate through the pia without buckling, but then softens and better matches the mechanics of cortical tissue. A process utilizing a parylene moisture barrier was developed to fabricate nanocomposite-based intracortical probes with integrated thin-film metal electrodes and interconnects. The electrode impedance was found to be 95.0 + 4.8 kΩ for an electrode 6000 µm<sup>2</sup> in area.</p><p>To develop a microfabricated neural array technology with on-board recording, stimulation and chemical sensing capabilities, a process was developed to integrate semi-metallic diamond microelectrodes into a flexible polymer substrate. Diamond-on-polymer microelectrode arrays were fabricated using a “diamond-first” fabrication process whereby the diamond electrodes were first grown on a Si/SiO<sub>2</sub> substrate, followed by the deposition and patterning of a polynorbornene capping layer, thin-film metal interconnects, and a polynorbornene substrate layer. A chemical release process in 49% HF was used to transfer the diamond from the Si substrate to the polymer substrate. Ohmic contact was made to diamond microelectrodes using Cr/Au metallization, without requiring an annealing step. Current pulse testing demonstrated potential for neural stimulation with diamond microelectrodes. The electrode impedance at 1 kHz was found to range from 300 kΩ to 8 MΩ, indicating that there are some electrodes suitable for neural recording. Finally, electrochemical detection of 100 µM dopamine in saline was achieved with a diamond-on-polymer electrode.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
EECS - Electrical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hess, Allison Elizabeth
Contributors dc:contributor
  • Zorman, Christian

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Hess, Allison Elizabeth. Integration of Process-Incompatible Materials for Microfabricated Polymer-Based Neural Interfaces. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=case1301687079