Back to search

Case Western Reserve University School of Graduate Studies

FEEDBACK CONTROL OF STANDING BALANCE USING FUNCTIONAL NEUROMUSCULAR STIMULATION FOLLOWING SPINAL CORD INJURY

Abstract

dc:description

Functional neuromuscular stimulation (FNS) has been used to restore basic standing capabilities to individuals with spinal cord injury (SCI). In current clinical practice, constant open-loop stimulation is applied to continuously activate extensor musculature and maintain erect standing. This leaves the user to stabilize against postural disturbances by using their arms to apply support loading on an assistive device or surface. The ability to reach and manipulate objects while maintaining standing posture with minimal effort is consequently compromised. The next major advancement in improving FNS standing function is employing feedback control to modulate stimulation levels and produce automatic postural corrections to balance against disturbances and facilitate ease of use. Previous investigations in closed-loop FNS standing have examined controlling individual joints along single planes of movement and demonstrated measurable improvements in disturbance rejection. However, optimal clinical standing function requires unconstrained, three-dimensional (3-D) movements actuated synergistically by multi-articulate musculature. This dissertation project investigates the potential of using feedback to control stimulation levels to paralyzed musculature spanning the ankles, knees, hips, and trunk for control of standing in 3-D against postural perturbations. Initially, model-based methods were developed to create control systems employing feedback of joint kinematics and total body center of mass (COM) acceleration. These systems were subsequently evaluated for performance, robustness to feedback error, and quantity of sensor-based feedback potentially required. Simulation results indicated that a significant reduction in user upper extremity (UE) loading against postural perturbations is feasible with feedback control compared to the clinical analog of constant, maximal muscle excitation. For laboratory evaluation, a control system utilizing COM acceleration feedback was created for a specific user of an FNS standing system with 16 channels of intramuscular stimulation. Compared to the baseline case of constant stimulation levels used clinically, feedback control reduced the mean UE loading applied by the user by 33% against external perturbations and by 27% during volitional reaching activity. Future work should consider applying these feedback control methods to additional participants with novel stimulation paradigms, creating validated user-specific model control systems, developing algorithms to quickly adapt controller parameters according to time-varying stimulated muscle output, and selectively incorporating joint feedback.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nataraj, Raviraj
Contributors dc:contributor
  • Kirsch, Robert

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Nataraj, Raviraj. FEEDBACK CONTROL OF STANDING BALANCE USING FUNCTIONAL NEUROMUSCULAR STIMULATION FOLLOWING SPINAL CORD INJURY. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=case1302482539