Back to search

Case Western Reserve University School of Graduate Studies

The Study of MEMS Acoustic Sensor for Totally Implantable Hearing-Aid System and Micropackage Technology for Implantable Devices

Abstract

dc:description

<p>PART I. A MEMS Acoustic Sensor for Totally Implantable Hearing Aid SystemsA piezoelectric vibration source was used to simulate the umbo vibration. Umbo vibration characteristics were extracted from literature and laboratory measurement data. By directly attaching to the Umbo in the human middle ear, this displacement sensor is able to pick up the natural vibration in the ear. This displacement sensor was expected to increase the sensitivity and has a flat frequency response in the frequency bandwidth from200 to 8000 HZ. The theoretical sensor model calculation proved the feasibility of this displacement sensor used as an acoustic sensor for hearing aid. In the laboratory test, this device can detect 40-dB SPL sound in the 1–2 kHz region, with 100-Hz channel bandwidth. The results of three different acoustic sensors, including an acceleration sensor are summarized and compared. A preliminary design of the implantable displacement sensor for totally implantable hearing-aid systems is also presented.</p><p>PART II. Micropackage Technology for Implantable Devices</p><p>Packaging is one of the critical processes for implantable MEMS biomedical systems. This thesis explored a non-hermetic multiple-film-layers micro-package technology. MDX 4210, FP 4450 and Parylene C are studied as packaging materials for the implantable micro-systems. These materials are coated on the comb figures structured PCBs and then merged into 40OC saline for a life time evaluation or 85OC saline for accelerated life time evaluation. The failed devices are tested for failure modes. A previously designed micro power telemetry unit is packaged using this technology for evaluation. The telemetry unit is able to measure bio-potential, resistance, temperature and pressure change along with a MEMS pressure sensor. The characteristics of this telemetry unit are measured. Packaged devices were immersed in 40°C saline solution for simulated life time evaluation. The first group of devices without Parylene C coating has a life time over 70 days in 40°C saline bath.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Sciences (Engineering)
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
EECS - Electrical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhang, Rui
Contributors dc:contributor
  • Ko, Wen H.

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Zhang, Rui. The Study of MEMS Acoustic Sensor for Totally Implantable Hearing-Aid System and Micropackage Technology for Implantable Devices. masters thesis, Case Western Reserve University School of Graduate Studies, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=case1310092220