Case Western Reserve University School of Graduate Studies
Interfascicular Interfaces for Peripheral Nerve Stimulation: Directed Stimulation within the Epineurial Space
Abstract
dc:descriptionAn interface implanted on or within the peripheral nerve provides the opportunity to stimulate a desired group of axons to control a single muscle or a group of muscles without requiring large current magnitudes. Intraneural electrodes can provide close access to the axons, but those that disrupt the perineurium can cause chronic damage to the nerve. Computational models have shown that directional electrical contacts placed within the epineurium, between the fascicles, and not penetrating the perineurium can achieve selectivity levels similar to point source contacts placed within the fascicle. This work examines the selectivity of an interface implanted within the epineurium, outside the fascicles without penetrating the perineurium. Further, the biomechanical characteristics and insertion into the membranes of the nerve are studied to identify the margins between the epineurium and the perineurium. This data is expected to aid insertion techniques and interface development for devices implanted within and outside the perineurium. The Young’s moduli and ultimate strains of the perineurium and the epineurium and the forces necessary to penetrate them for electrode implant were quantified.Data suggested that the Young’s modulus and the insertion forces were both an order of magnitude lower for the epineurium than the perineurium. These data provide design parameters that can be used to engineer materials that mechanically match the individual tissue membranes and facilitate implant mechanics suitable for each tissue.Further, this work tests the hypothesis that directional interfascicular contacts distributed in the epineurial space are selective. Examination of the recruitment data demonstrated selective axon population recruitment by these interfaces. Interfascicular interfaces with a directed contact were able to provide selective recruitment of axons without penetrating the perineurium.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Koppaka, Smruta
- Contributors dc:contributor
-
- Tyler, Dustin
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1370004170