Case Western Reserve University School of Graduate Studies
Optimization of High Density Nerve Cuff Stimulation in Upper Extremity Nerves
Abstract
dc:descriptionThe overall goal of this work is to optimize nerve cuff stimulation for selective activation of upper extremity nerves. The characterization of upper extremity nerve dimensions is important for electrode design development. Quantitative measures such as nerve diameter, number of fascicles, and fascicle diameters were used to guide neural electrode dimensions. The quantitative upper extremity measurements were used as a template to create upper extremity simulation models.We constructed physiologically based Finite Element Method (FEM) models of nerve cuff electrodes at low, moderate, and high contact densities at 16 nerve locations in median, ulnar, and radial nerves. We hypothesize that adding two flanking anodes to an active cathode is sufficient for optimal selectivity of fascicles in upper extremity nerves. We exhaustively tested one and two channel configurations, as well as, all three channel configuration within six contacts. Since the number of permutations of stimulation parameters increases exponentially by adding anodes, a genetic algorithm search routine was employed. Seventy-nine percent of all fascicles were selectively activated with high density electrodes and multiple channel stimulation. Only 2.5% of selective fascicles required more than 2 anodes in the stimulation configuration. The important implication of this work is that optimal system design requires high density nerve cuff electrodes, but no more than four simultaneously active stimulation channels routed through a multiplexor. We tested the capabilities of a high density electrode with multipolar stimulation in non-human primate upper extremity nerves. A high density Composite Flat Interface Nerve Electrode (CFINE) was implanted chronically in a non-human primate on the median, radial, and ulnar nerves. Electromyography (EMG) recordings were used to optimize nerve stimulation parameters to increase selective muscle activation of the hand and arm muscles using high density nerve cuffs with multipolar stimulation. The non-human primate nerves resembled human nerve simulations that had demonstrated limited selectivity improvements with multipolar, high density nerve cuffs. High density nerve cuffs with multipolar stimulation in non-human primates, however, increased the number of permutations of muscle activation sets in the non-human primate animal model when compared to single channel stimulation in low density nerve cuffs.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Brill, Natalie Amber
- Contributors dc:contributor
-
- Tyler, Dustin
Subjects
dc:subject × 13Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1418147191