Back to search

Case Western Reserve University School of Graduate Studies

Extracting Voluntary Activity of Fascicular Sources within Peripheral Nerves with Cuff Electrodes

Abstract

dc:description

Objective: The advancement of multi-degree of freedom prosthetic limbs designed for amputees increases the demand for a reliable interface with the peripheral nervous system from which command signals to control these prostheses can be extracted. Several approaches have been explored to extract these signals including the recording flat interface cuff electrodes (rFINE). The rFINE approach has been shown to be safe and stable and has been used to restore sensation through functional neural stimulation in humans. However, the rFINE capability for long-term functional selective recording has not been investigated. This study aims to extract fascicular-level voluntary activity from intact nerves using the rFINE needed to realize an intuitive, bi-directional integration of advanced bionic limbs using FINE interface.Methods: 16-contact flexible rFINEs were developed and implanted on the sciatic nerve of dogs proximal to the tibial and common peroneal bifurcation point, to access the neural activity controlling ankle movement. The neural signals were recorded with the animal walking on treadmill, and the ankle movement was simultaneously tracked. The activity was then processed using a beamforming algorithm (spatial filter) to independently recover the activity of the two main fascicular sources inside the nerve. The recovery outcome was compared with the observed ankle movement. These recordings were maintained for up-to 9 months invithree animals. Post-mortem histological analyses were performed to identify the true fascicle locations and were compared with the predicted locations. Cuff impact on the nerve was also examined and quantified by measuring the G-ratio of the axons at various levels along the implanted nerves. The recording amplifier was then redesigned into a fully implantable device, and was tested by recording physiological activity from the implanted rFINEs under the same conditions previously tested with the external device.Results: The rFINE designed for these experiments was capable to record neural signals with quality estimated with SNR of 3.65-7.59dB and total input referred baseline noise of 0.62-1.00 µVRMS in the three studied animals. Contact impedance was stable with values between 2.04 and 4.32 kO. The recorded activity was used to recover individual fascicular activity that matched the observed ankle movement with accuracy of >0.85 quantified by the area under the ROC. Post mortem analysis showed that the recovered sources were located within 0.75 ±0.38 mm from the nearest major fascicle, and the G-ratio at the proximal and distal segments of the implanted nerve axons were observed to be 0.545±0.091 and 0.545±0.094 respectively, whereas a lower value of 0.532±0.117 was observed at the medial segment. These results indicate that the impact of the rFINE on the nerve was small and localized at the cuff level. Finally, an implantable low-noise and low power recording device was developed and built using hardware averaging noise reduction technique. Recording baseline noise of 0.68±0.02 µVRMS and SNR of 2.78 ± 0.25 dB was achieved from chronic recordings of the rFINE with the use of 8 parallel input amplifiers.viiSignificance: Selective recording of voluntary fascicular activity within an intact nerve using the rFINE was observed to be both feasible and reliable in a chronic animal preparation. The signal recovered is an estimation of the animal’s intent to control the ankle movement through a single nerve. The recovery was maintained during the implant duration with consistent accuracy, SNR and interface impedance. Therefore, the results indicate that the information needed to generate a simple ankle movement can be recovered with the rFINE. However, the signals’ amplitudes are still low and the study is limited to a single degree of freedom. Combining the technology developed in this study with the current advancement of the robotics and functional neural stimulation could lead to a stable bi-directional integration of bionic limbs for amputees using the flat interface nerve electrode approach.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dweiri, yazan M.
Contributors dc:contributor
  • Durand, Dominique
  • Gustafson, Kenneth

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Dweiri, yazan M.. Extracting Voluntary Activity of Fascicular Sources within Peripheral Nerves with Cuff Electrodes. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=case1449247553