Abstract

dc:description

We think that we can help ease patients’ concerns by altering diagnostic x-rays. Our goal is to use CT information to pre-surgically determine the likelihood of success of an operation. This technique could help expectation setting or, moreover, could help oral physicians make procedural decisions which result in higher rates of implant stability and functionality.Currently, cone beam computerized tomographies (CBCT) are commonly used in the dental community for morphological assessment of the mandible and maxilla. Previous studies have shown the potential of using a single set of phantoms in the oral cavity, to derive Hounsfield Units (HU). However, due to the polychromatic x-ray source in CBCT scanners, variation in average grey level for a single phantom exists, as a function of location.This thesis will focus on using common biomaterials, used in biomedical implants, to design and fabricate a set of standards, small enough so that a single set is fixed adjacent to the region of interest (ROI). This set of phantoms would allow dental clinicians to quantitatively assess bone quality by ultimately comparing derived HU to mass density without the need for expensive medical software.

Degree

thesis:*
Name thesis:degree_name
Master of Sciences
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Varghai, Kaveh, Varghai
Advisor dc:contributor.advisor
  • Eppell, Steven

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Varghai, Kaveh, Varghai. The Production of Hydroxyapatite Standards, Used for Post CBCT Scan Hounsfield Unit Calibration. masters thesis, Case Western Reserve University School of Graduate Studies, 2018. http://rave.ohiolink.edu/etdc/view?acc_num=case1505842174493682