Case Western Reserve University School of Graduate Studies
Anatomically-Versatile Peripheral Nerve Electrodes Preserve Nerve Health, Recruit Selectively, and Stabilize Quickly
Abstract
dc:descriptionPeripheral nerve cuff electrodes (NCEs) have been deployed in neuroprostheses restoring or modulating motor, sensory, and autonomic functions. They address myriad pathologies including stroke, spinal cord injury, amputation, seizure, chronic pain. As these applications encompass more indications, NCEs may be deployed in more anatomically-challenging locations while still delivering selective and stable stimulation and preserving the health of the implanted nerves. A novel class of reshaping electrodes with patterned regions of stiffness enable implantation in a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. We introduce the composite flat interface nerve electrode (C-FINE), flexible and small enough to be suitable for implantation near joints or other constrained locations. Benchtop testing verified the C-FINE does not exert ischemia-inducing pressure on nerves, even in the face of potential nerve swelling. Animal testing verified safety of C-FINE shells implanted on peripheral nerves for 3 months through a combination of nerve conduction studies and quantitative histology.Classically, this benchtop and animal testing followed by chronic observation of neuroprosthesis function have served as a proxy for directly measuring nerve health. We implanted the first-in-man C-FINEs on the proximal femoral nerves near the inguinal ligament of a man with cervical spinal cord injury. Over the first year of implantation we established the safety of C-FINEs in this anatomically constrained location directly via clinical electrodiagnostics. Future NCE designs can use these clinical results as a baseline for expected changes in a well-functioning neuroprosthesis. Previous NCEs have not been able to selectively activate hip flexors and knee extensors when implanted at the proximal femoral nerve. With 8 contacts and the potential to gently reshape the nerve, the C-FINEs selectively separated these functions and also recruited independent populations of knee extensors. We further established the reliability of intraoperative predictions of C-FINE performance through chronic use, and the expected time-course of NCE stabilization using electromyography intraoperatively and postoperatively. We find that the C-FINEs are selective at this location and their function stabilizes quickly.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Freeberg, Max J.
- Advisors dc:contributor.advisor
-
- Triolo, Ronald
- Tyler, Dustin
- Chair dc:contributor.committeechair
-
- Durand, Dominique
Subjects
dc:subject × 13Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1509114024578108