Back to search

Case Western Reserve University School of Graduate Studies

Radiofrequency Induced Heating of Implanted Stereo-electroencephalography Electrodes During MRI Scan: Theory, Measurements and Simulations

Abstract

dc:description

Magnetic Resonance Imaging (MRI) has become an important imaging method in the field of medical diagnostics and therapy due to its soft tissue contrast and use of non-ionizing radiations (unlike CT and X-ray). However, MRI also presents a number of safety issues including RF induced heating created by the interaction of the RF electromagnetic fields with human tissue and possible medical implants. A particular and important concern arises in the presence of any electrically conducting implant within the imaging specimen. The coupling between the conducting implants and RF electromagnetic fields produces relatively strong electrical currents within the implant and surrounding tissue which lead to ohmic heating and possibly unsafe temperature rises that damage tissue.One type of implant, and the focus of this thesis, are Stereo-electroencephalography (SEEG) electrodes. The SEEG electrodes are partially inserted into the brain of epilepsy patients for the localization and monitoring of focal epileptic zones. The electrical contacts on the SEEG electrode within the brain are connected via signal wires to external instrumentation to monitor the electrical activity in the brain. In this work, we study the RF induced heating due to the SEEG electrodes using both experimental measurements and numerical simulations. As a means for improved understanding of RF heating with implants containing both internal and external conductors, and to help validate the agreement between simulations and experiment, studies were first performed with a single insulated conducting copper wire using an MRI phantom. The benchmark for characterizing the level of RF heating was the temperature rise within the phantom and near the implants. These studies were then extended to include an 8 contact SEEG electrode, and then configurations with multiple wires and multiple SEEG electrodes.The results of the study demonstrate the importance of the length of the SEEG electrode and the signal wires on the extent of the RF heating and concomitant temperature rise. A resonant effect was observed when the length of the external portion of the SEEG electrode is one-quarter of the wavelength of the RF field resulting in the maximal temperature rise. Conversely, the heating was minimal when the length of the external portion was equal to one-half of the wavelength. This resonant- antiresonant pattern repeats for every one-quarter wavelength added to the length of the external portion. For a 3 T MRI system, the first resonant length was measured to be 70 cm and the first antiresonant length was measured to be 130 cm.Important for safety considerations is not only the dependence of the RF heating on the geometry of the implants, but also the absolute temperature rise, which needs to be below 1 °C. In these studies a Turbo Spin Echo (TSE) imaging sequence was used due to its relatively large RF power deposition. Using the TSE facilitated the measurement of the temperature rise, although clinical scans with SEEG electrodes are performed with lower power imaging sequences leading to lower temperature rises. For the TSE sequence, with a Specific Absorption Rate (SAR) of 2.8 W/kg within the head, the temperature increase for a single wire was experimentally measured to be as large as 8.9 °C when the wire was at the resonant length and below 0.5 °C when the wire was at the antiresonant length. When an 8 contact SEEG electrode was used instead of the wire, the maximum heating was found to be 4.2 °C at resonant length and less than 0.5 °C at antiresonant length.Coupling between the individual wires inside a single 8 contact SEEG electrode was also considered. We find a significant RF coupling between individual wires within an SEEG electrode, such that the length of any one of the 8 signal wires has an effect on the temperature rise at the contact points associated with the other wires. In other words, the temperature rise increased at all the SEEG contact points within the phantom even if only one of the wires was at the resonant length.Finally, the effect on RF heating of multiple implants was considered. It was found that the heating using two separate copper wires differed from the heating of an individual wire, and the heating could be either larger or smaller than in the case of a single wire. For two copper wires entering the phantom from the same lateral side, the coupling between the wires, when one was at the resonant length and the other at the antiresonant length, resulted in an increased temperature rise by about 50% compared to a single wire alone at the resonant length. This perhaps surprising result – the fact that adding a wire at the antiresonant length can increase the temperature – is understood using well developed antennae theory and explained in this thesis. In a situation where two copper wires entered the phantom on opposite lateral sides, the temperature rise with both wires at the resonant length resulted in a 50% increase as compared to the situation with only a single wire at resonant length. However, when both the wires placed at either side of the phantom were at antiresonant length, the coupling did not increase the heating significantly.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bhusal, Bhumi Shankar
Contributors dc:contributor
  • Martens, Michael

Subjects

dc:subject × 18

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Bhusal, Bhumi Shankar. Radiofrequency Induced Heating of Implanted Stereo-electroencephalography Electrodes During MRI Scan: Theory, Measurements and Simulations. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2019. http://rave.ohiolink.edu/etdc/view?acc_num=case1545139929613149