Case Western Reserve University School of Graduate Studies
Automated Plaque Characterization of Intravascular Optical Coherence Tomography (IVOCT) Images Using 3D Cryo-image/Histology Validation
Abstract
dc:descriptionIntravascular optical coherence tomography (IVOCT) is a high-resolution (10-20 µm), high-contrast, catheter-based imaging technology that can identify major coronary plaques types (fibrous, lipid, and calcium). However, with >500 images generated in a single 2.5 second scan, automation is needed to facilitate live-time clinical use and off-line assessment of drug therapeutics. Therefore, we developed machine learning approaches for automated plaque characterization using cryo-imaging/histology for validation. However, we confronted a challenge in that IVOCT images are obtained perpendicular to the imaging catheter, while cryo-image volumes display the true 3D vessel geometry at a higher sampling rate. Our solution was to develop a specialized 3D registration algorithm, where we placed a virtual catheter within the cryo-image volume and extracted perpendicular, reformatted images, thus mimicking IVOCT image acquisition. Registration was performed on 10 different vessels, resulting in 441 registered IVOCT and cryo-image pairs, where z-registration accuracy was determined to be -25.0±185.4 µm. Furthermore, by referencing the registered cryo/histology images, IVOCT images were annotated to identify major coronary plaque types. We also expanded this database to include in vivo images, which were annotated using two-expert consensus. This resulted in a dataset of ~7000 annotated IVOCT images. We then used our dataset to train/test a variety of machine learning methods to determine the optimal approach for identifying fibrocalcific and fibrolipidic A-lines in IVOCT images. We used a comprehensive feature set of hand-crafted features, which included features from previous studies (e.g. optical attenuation and A-line peaks). Additionally, we introduced novel vascular lumen morphology and 2D/3D digital edge features. We found that use of a 3-class SVM with mRMR feature selection to have the best performance on our data. This approach had true positive rates on a held out test set (>1700 images) of: 81.4, 94.5, and 74.8 for other, fibrolipidic, and fibrocalcific A-lines, respectively. We found that inclusion of our novel morphological and 3D features improved classification accuracy. Finally, we demonstrated proof-of-concept for streamlining A-line classification output with existing fibrolipidic and fibrocalcific boundary segmentation methods, to enable fully automated plaque quantification. Results are very encouraging, and suggest that with further development, our technology can be implemented for live-time use in the cardiovascular catheterization lab, or for offline use for evaluation of drug and biologic therapeutics.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Prabhu, David
- Advisor dc:contributor.advisor
-
- Wilson, David
- Chair dc:contributor.committeechair
-
- Rollins, Andrew
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1556293860943414