Back to search

Case Western Reserve University School of Graduate Studies

Onset of Numbness in Hand-Arm Vibration Syndrome

Abstract

dc:description

This thesis studied hand exposure to vibration from a power hand tool for an understanding of the time to onset of numbness in the fingers. The goal was to use the study to develop predictive algorithms for time to onset of numbness in different individuals. A commercial orbital sander supported on a custom wood box was used as the vibration source. The sander was instrumented with a wireless 3-axis acceleration microsystem to measure vibration acceleration exposure during the experiments. The acceleration data and time to onset of numbness were used to calculate the 8-h energy equivalent frequency-weighted vibration, A(8). The experimental environment was at normal room temperature; the temperature was monitored to verify that it was essentially constant during all of the experiments. Nine subjects were recruited for this study—all healthy mails 23 to 33 years old; this study is referred to hear as “inter-subject”. Each subject completed a prescribed procedure for each experiment based on an approved university Internal Review Board application. The experiments instructed the subjects to grasp the handle of the sander, after which the sander was turned on for a specific duration. The onset of numbness times were determined by the binary search method and 2-point test. However, the onset times and the A(8) values varied significantly among the inter-study subjects. The average and standard deviation for the onset of numbness time were 7.97 and 7.90 minutes, respectively. The average and standard deviation for A(8) were 2.34 and 1.09 m/s2, respectively. A new study was designed and approved to assess the utility of A(8) as a determinant of vibration exposure. This study—referred to here as “intra-subject”—used one of the subjects of the inter-subject study. In preparation, the experimenter underwent a session of expert training for the 2-point test. A force sensor was also added to the instrumentation to help the subject maintain a constant grip force of about 1N on the sander’s handle during the experiments. The intra-subject experiments compared the effect on one participant under three vibration intensities—a feature available on the sander. Repeated binary searches were also used to increase the quality of the statistical analysis. The results showed A(8) to be a valid determinant of vibration exposure. The improvements in instrumentation and experimental procedure of the intra-subject experiment are expected to facilitate a better future inter-subject study.

Degree

thesis:*
Name thesis:degree_name
Master of Sciences (Engineering)
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
EECS - Electrical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhang, Tianxiang
Contributors dc:contributor
  • Mehregany, Mehran

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Zhang, Tianxiang. Onset of Numbness in Hand-Arm Vibration Syndrome. masters thesis, Case Western Reserve University School of Graduate Studies, 2019. http://rave.ohiolink.edu/etdc/view?acc_num=case156034480179182