Case Western Reserve University School of Graduate Studies
Data-Driven Evaluation of HVAC Systems in Commercial Buildings and Identification of Savings Opportunities
Abstract
dc:descriptionCommercial buildings account for around one third of the total electricity consumption in the United States, of which a significant amount is wasted. Heating Ventilation and Cooling (HVAC) systems are one of the largest components of the overall energy consumption in buildings and by improving the operational condition and efficiency of HVAC systems, significant savings can be achieved. Quantification of HVAC performance and characteristics is a critical step in the diagnostics, prognostics, and improvement of savings opportunities. Identifying savings through virtual energy audits using widely available smart-meter time-series data of the total energy consumption is an efficient and robust procedure that can be applied to a large number of buildings' datasets.In this study, we will develop a systematic, automated, and scalable pipeline for quantifying HVAC characteristics from the total energy consumption of smart-meter data to identify savings opportunities in commercial buildings and determine the critical affecting parameters. The automated pipeline layout will not only structure, clean, ingest, and interactively analyze the data, but also utilize the high performance computing cluster (HPC) and a smart job scheduler that we developed in addition to existing resources. Then, two main HVAC savings opportunities of rescheduling and baseload savings through setpoint setback will be quantified and discussed, and the results will be scaled to a statistically significant population of buildings across the US for comparative analysis. We will identify and discuss target buildings with the highest savings opportunities. Then, we will propose a data-driven method for setting back the setpoint of HVAC cooling by 1 degree increments on data and quantify the associated savings followed by a comparative study on the population and variable importance analysis, accordingly. As a result of the automated pipeline, 816 buildings' datasets across the United States have been processed efficiently, with significant improvement in data quality, and a processing time of 34 minutes which is 86 times faster than a sequence pipeline. Also, through a population study, we will illustrate that with applying the proposed HVAC savings to each dataset at cooling degree days, when the average daily temperature is above HVAC cooling setpoint, unoccupied time baseload and rescheduling savings with the median of 1.63% and 2.12% reduction from annual energy consumption can be obtained, respectively.Furthermore, by setpoint setback analysis, we will demonstrate that air conditioning in commercial buildings account for $9.5\%$ of the total energy consumption and with one degree setback, 1.1% of the annual energy consumption is reduced with retail and office buildings containing the highest potential.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- EECS - System and Control Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Khalilnejad, Arash
- Advisors dc:contributor.advisor
-
- Abramson, Alexis
- French, Roger
- Chair dc:contributor.committeechair
-
- Loparo, Kenneth
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1579662167776891