Case Western Reserve University School of Graduate Studies
Fast Modeling of the Patient-Specific Aortic Root
Abstract
dc:descriptionThe aortic root is a significant cardiac organ, which transports the blood from ventricle to the rest of our body. Nowadays a great number of finite element models of the patient-specific aortic root have been constructed to analyze the pathology of individual patient. However, the methodology to generate a valid patient‐specific aortic root model in a fast speed is not available. The current methods resort either to reconstruction of aortic root from sliced pictures of MDCT or to manual construction from commercial CAD applications, which is accurate but not efficient. In this thesis, we offer a robust and efficient algorithm called Fast Patient‐specific Aortic Root Generation Algorithm (FPAG) to generate the finite element model of the patient‐specific aortic root in a very fast speed.A couple of critical parameters that define the geometry of the patient‐specific root and valve will be extracted from the pictures created MDCT & 3D echocardiogram. Then we use B‐rep to build the skeleton curves and use Delaunay triangulation algorithm to mesh the patient‐specific aortic root model. The process of generation of the B‐rep curve and the Delaunay mesh for the patient‐specific aortic root is very speedy. The result of the FPAG algorithm will be a patient‐specific meshed aortic root model that is discretized by tetrahedral mesh. Currently, the FPAG algorithm is coded in Matlab. There is a good agreement in terms of geometry between the patient‐specific aortic root modelsconstructed by FPAG and the one reconstructed by MDCT. The dynamics of a tricuspid patient‐specific aortic valve constructed by FPAG is validated by the finite element analysis (FEA). The valve is applied by the physiologically realistic pressure condition in a cardiac cycle. The dynamic test of the valve shows a good compatibility with that of pre-validated aortic valve. By minor modifications of the FPAG algorithm, patient‐specific bicuspid aortic valve can also be generated. Although some detailed features of the aortic root will be dismissed compared with the MDCT reconstructed model, the patient‐specific aortic root generated by the FPAG algorithm is accurate enough for future postprocessing use by both cardiologists and mechanic engineers.
Degree
thesis:*- Name thesis:degree_name
- Master of Sciences (Engineering)
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- EMC - Mechanical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Li, Jiayuan
- Chair dc:contributor.committeechair
-
- Li, Bo
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1612364612715906