Case Western Reserve University School of Graduate Studies
BIOMIMETIC MICROFLUIDIC PLATFORMS FOR ASSESSING RED BLOOD CELL DEFORMABILITY AND MICROVASCULAR OCCLUSION
Abstract
dc:descriptionCellular biophysical properties strongly regulate critical cell functions. Micro-engineered biomimetic platforms provide precisely controlled physiologic flow environments, which enables robust, accurate characterization of complex cell behavior and properties. These technologies have remarkably advanced cell biomechanics studies, such as measurement of red blood cell (RBC) deformability and adhesion in sickle cell disease (SCD), and evaluation of surface biomarker expression level of precancerous cells.The deformability of RBCs plays a pivotal role for their traversing through the narrowest blood vessels in the microvasculature, which is paramount for oxygen and nutrient delivery to as well as waste removal from the tissues and organs in body. However, in various microcirculatory diseases, the deformability of RBCs is pathologically altered. To date, a number of microfluidic platforms have been developed to measure abnormal RBC deformability in diseases; however, these platforms either do not mimic the capillary bed architecture, or they are low-throughput and limited in testing clinical samples at near-physiologic hematocrit. In Chapter 2, a novel microfluidic platform, OcclusionChip, that consists of two side passageways and a series of embedded micropillar arrays forming uniform narrow openings within each arrays but overall finer openings along the flow direction, mimicking the arteriovenous anastomoses and the continuously changing blood vessels in the capillary bed, was developed for assessment of RBC deformability and the associated microvascular occlusion. Leveraging the OcclusionChip technology, RBCs from various pathological conditions, including non-specific protein cross-linking, cytoskeletal-specific stiffening, heavy metal toxin, storage lesion, malaria, and SCD, were tested, and the overall RBC deformability of individual samples was measured by a new parameter, Occlusion Index (OI). Heterogeneity in OI profiles was reported and correlated with fetal hemoglobin (HbF) levels in the study subjects with SCD. A hypoxic version of OcclusionChip assay was also developed, and significantly elevated OI levels were observed and correlated with sickle hemoglobin (HbS) levels in the study subjects with SCD.Close monitoring of RBC deformability and microvascular health is critical for patient stratification and early therapeutic intervention in SCD. In Chapter 3, clinical blood samples from subjects with HbSC disease or homozygous HbSS SCD as well as from healthy controls (HbAA) were assessed and compared using OcclusionChip assay. Kernel density estimation of OI profiles in the population with HbSS revealed two sub-groups with distinct clinical phenotypes, which associated with clinical diagnosis of pulmonary shunting and hydroxyurea responsiveness in the population.Most microfluidic technologies for RBC deformability measurement require a high-resolution imaging process, which significantly hinders their translation to point-of-care tests. Electrical measurement is widely adopted in microfluidic designs largely due to its simplicity, efficiency, and its potential for adaptation for point-of-care tests. In Chapter 4, a novel microfluidic platform integrated with micropillar arrays and sensing electrodes was developed for electrical impedance measurement of RBC deformability and the associated microvascular occlusion. RBC deformability, measured by two new, highly correlated parameters, RBC Occlusion Index (ROI) and RBC Electrical Impedance Index (REI), of blood samples from subjects with SCD and hereditary spherocytosis (HS) was reported. Further, associations between the measured ROI and REI and clinical treatment outcome in SCD was reported.Concurrent assessment of two biophysical properties of RBCs, the membrane adhesiveness and cellular deformability, will significantly benefit more comprehensive disease state characterization and therapeutic outcome evaluation in SCD. In Chapter 5, the OcclusionChip assay was integrated with surface functionalization for microfluidic concurrent assessment of RBC adhesion to laminin (LN) and RBC-mediated microcapillary occlusion. Clinical blood samples from 4 healthy donors (HbAA), 5 subjects with SCT (HbAS) and 18 subjects with HbSS SCD were tested in the LN-functionalized OcclusionChip assay. Results were compared among different groups, and clinical associations of the two hemorheological biomarkers were reported to associate with vascular hemolysis and iron overload in SCD.Currently, ektacytometry is widely used in both research and clinical laboratory settings for RBC deformability measurement. However, it measures the average deformability of bulk cells, which is limited in probing small fraction of RBCs with abnormal deformability. In Chapter 6, the process reproducibility of the OcclusionChip assay and with a commercially available ektacytometry was analytically validated. Thereafter, OcclusionChip assay and ektacytometry measurement were simultaneously carried out on normal RBC samples mixed with glutaraldehyde-stiffened RBCs at gradient concentrations (0% (as control), 0.01%, 0.1% and 1%), and on clinical blood samples from a healthy donor (HbAA), a subject with sickle cell trait (SCT, HbAS), a subject with HbSS SCD who received allogeneic hematopoietic stem cell transplant, and a subject with HbSS SCD without any curative therapies. OcclusionChip assay was found more sensitive than ektacytometry in differentiating samples with different glutaraldehyde-stiffened RBC concentrations and in probing the decreased RBC deferability under hypoxia in the samples from the HbAS subject and the HbSS subject with HSCT.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- EMC - Mechanical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Man, Yuncheng
- Advisor dc:contributor.advisor
-
- Gurkan, Umut
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1635172632458131